DIAGNOSTIC FUNCTIONS:
LCD DISPLAY MSG DESCRIPTION FAILURE MODE
FLT Fault General fault for Over Temperature/Module Fault
OCT Over Current Trip Supply has exceeded the over current protection level.
OVT Over Voltage Trip Supply has exceeded the over voltage protection level. (Allow 7s to clear OVT)
ESD External Shut Down Output disabled by J1 (analog control port) in Local Mode
RMT Digital Remote Operation (PC) The SPS power supply is controlled by a remote PC
Important Notes:
•
The FLT fault message indicates a general fault and is triggered by one of the following failure modes, A) Over-temperature and B) Module Fault.
•
In Master/Slave Mode, the Slave unit(s) will display “ *SLAVE MODE* ” and individual slave voltage and current read back will be disabled. Please note, the *SLAVE MODE* message is
not a fault indicator and is used to indicate the power supply is operating in Slave Mode.
•
In Master/Slave Mode, the master will display the total voltage and current read back of all the connected units. Alarms will latch until PROT/CLEAR button or PROT:CLE command executed.