Remote Operation
5-40 M370430-01 Rev F
Table 5-12 OPERation Status Register
Indicates that the supply is in CALibration Mode.
Reflects the summary of the SHUTdown
Sub-Register.
Reflects the summary of the CSHare Sub-Register.
Reflects the output mode of the supply.
Reflects the output mode of the supply.
Indicates if an Autosequence program is currently
running.
The operation shutdown status register describes the cause of the power
supply shutting down the output. More than one bit may be active and
multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have
caused the power supply to shutdown.