EasyManua.ls Logo

Ametek Sorensen XG 33-25 User Manual

Ametek Sorensen XG 33-25
399 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
PROGRAMMABLE POWER
M370430-01 Rev F www.programmablepower.com
XG Family Programmable DC
Power Supply
Operating Manual
(firmware v 2.0 and higher)
670 Watts 1700 Watts
Half Rack
Full Rack
6 V to 600 V Models:
6-110
6-220
6-220
8-100
8-187.5
8-200
12-70
12.5-120
12-140
20-42
20-76
20-84
33-25
30-50
33-50
40-21
40-38
40-42
60-14
60-25
60-28
80-10.5
80-19
80-21
100-8.5
100-15
100-17
150-5.6
150-10
150-11.2
300-2.8
300-5
300-5.6
600-1.4
600-2.6
600-2.8

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen XG 33-25 and is the answer not in the manual?

Ametek Sorensen XG 33-25 Specifications

General IconGeneral
BrandAmetek
ModelSorensen XG 33-25
CategoryPower Supply
LanguageEnglish

Summary

Installation

Basic Setup Procedure

Provides a summary of the essential steps required for installing the power supply.

Step 3: Connecting AC Input Power

Describes the procedures and safety precautions for connecting the AC input power.

Step 4: Selecting Load Wires

Offers recommendations for selecting appropriate load wires based on current carrying capacity.

Step 5: Performing Functional Tests

Outlines the functional tests to perform after installation to verify proper operation.

Step 6: Connecting Loads

Describes how to properly connect loads to the DC output terminals of the power supply.

Step 7: Connecting Remote Sensing

Explains the procedure for connecting remote sensing wires to the load for accurate voltage regulation.

Local Operation

Operating Modes

Details the three operating modes: Constant Voltage, Constant Current, and Constant Power.

Alarms and Errors

Explains the various alarms and error conditions that can occur and their precedence.

Using Over Voltage Protection (OVP)

Details the Over Voltage Protection feature and its configuration for load safety.

Analog Programming (APG) and Isolated Analog Programming (ISOL)

Remote Operation

Configuring Remote Control Using RS-232

Provides detailed steps for configuring remote control via the RS-232 serial interface.

Configuring Remote Control using the USB Connector

Guides on setting up remote control using the USB interface and installing necessary drivers.

Communications Options

Calibration and Troubleshooting

Main Voltage and Current Calibration Principle

Explains gain error and offset error as sources of analog programming error.

Step 1: Gain Calibration

Provides the procedure for calibrating the gain of the voltage and current outputs.

Step 2: Offset Calibration

Provides the procedure for calibrating the offset of the voltage and current outputs.

Calibrating the Output Voltage

Details the process for calibrating the output voltage, including gain and offset adjustments.

Calibrating the Output Current

Details the process for calibrating the output current, including gain and offset adjustments.

Over Voltage Protection Calibration

Describes the procedure for calibrating the Over Voltage Protection (OVP) setting.

Troubleshooting for Operators

Provides guidance for operators on troubleshooting common issues and symptoms.

Error Messages

Error Messages

Explains how errors are placed in a queue and how the error queue is cleared.

Command Error List

Lists IEEE 488.2 syntax errors detected by the instrument's parser, including error codes and descriptions.

Execution Error List

Details errors detected by the instrument's execution control block, including parameter and setting conflict errors.

Specifications

Rack Mount Options and Installation Instructions

Related product manuals