PROGRAMMABLE POWER
M370430-01 Rev F www.programmablepower.com
XG Family Programmable DC
Power Supply
Operating Manual
(firmware v 2.0 and higher)
670 Watts – 1700 Watts
Half Rack
Full Rack
6 V to 600 V Models:
6-110
6-220
6-220
8-100
8-187.5
8-200
12-70
12.5-120
12-140
20-42
20-76
20-84
33-25
30-50
33-50
40-21
40-38
40-42
60-14
60-25
60-28
80-10.5
80-19
80-21
100-8.5
100-15
100-17
150-5.6
150-10
150-11.2
300-2.8
300-5
300-5.6
600-1.4
600-2.6
600-2.8

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen XG 40-21 and is the answer not in the manual?

Ametek Sorensen XG 40-21 Specifications

General IconGeneral
BrandAmetek
ModelSorensen XG 40-21
CategoryPower Supply
LanguageEnglish

Summary

Important Safety Instructions

WARNING: High energy and high voltage

Warns about potential hazards associated with high energy levels and stored energy in the power supply.

WARNING: Fire hazard

Instructs to operate the power supply in a non-flammable environment and avoid unauthorized modifications.

WARNING: Limitations on use

States the XG DC Power Supply is not intended for life support or medical equipment.

2 Installation

Basic Setup Procedure

Provides a summary of the basic setup procedure for the XG Family power supply.

Step 3: Connecting AC Input Power

Provides safety warnings and instructions for connecting the AC input power to the power supply.

3 Local Operation

Configuring Settings from the Front Panel

Explains how to configure settings and navigate the front panel controls of the XG power supply.

Alarms and Errors

Describes various conditions that can cause alarms, their precedence, and how to clear them.

Using Over Voltage Protection (OVP)

Details the Over Voltage Protection circuit and how to set the OVP trip point.

4 Analog Programming (APG) and Isolated Analog Programming (ISOL)

Analog Programming (APG) Connector J1

Details the pins and functions of the APG connector for analog programming and monitoring.

5 Remote Operation

Hardware and Connection Setup

Provides information on setting up hardware and connections for various remote interfaces.

Status Reporting in SCPI

Explains the status reporting implemented in the XG, dictated by the SCPI standard.

6 Communications Options

7 Calibration and Troubleshooting

APPENDIX B Error Messages

Command Error List

Lists IEEE 488.2 syntax errors detected by the instrument's parser.

Execution Error List

Details errors detected by the instrument's execution control block.

APPENDIX C Specifications

APPENDIX D Rack Mount Options and Installation Instructions

Related product manuals