TR-2100 User Manual 70
Status Relays
Type Solid State
Number of outputs 4
Contact rating 1 Amp max
400 V dc / 280 Vac max
Power & on line are N/C
Attention & triggered are N/O
Indication Power OK
System on line
Attention
System Triggered
Isolation Input to output - 2500 V ac
Contact to contact - 600 V dc
Power Supply
Input voltage options 88 - 370 V dc, 85 - 264 V ac
24 / 48 V dc optional
Power requirement 120 VA Max.
Backup batteries Internal batteries for real-time clock and parameter
memory
Cooling Long life fans on rear panel & processor
Voltage Withstand
Isolation 2.5 kV RMS for 1 minute, Channel to channel, channel
to ground. (per IEC 255-5)
2.15 kV dc for PSU (Power Supply Unit)
Impulse voltage withstand 5 kV, 1.2/50 µs. 0.5 Joule
(per IEC 255-5)
Surge withstand 2.5 kV, 1 MHz damped sine wave
(per IEC 255-22-1; IEEE/ANSI C37.90.1-1989)
RFI (per IEC 801 -3 & IEC 801-6 & IEEE/ANSI C37.90.2)
ESD (per IEC 801-2)
Enclosure
Cabinet Steel 19" rack mounting cabinet