APH 6530 ACEforce APH 100-20 ACEforce
Drive
hydraulic
Control (forward/reverse)
hydraulic
4. Operating speed
0 - 37 m/min 0 - 28 m/min
5. Vibration
Centrifugal power 65 kN 80 kN
Vibration frequency 55 Hz 40 Hz
6. Superficial power
Base unit
w. mount. brackets 75 mm
w. mount. brackets 150 mm
up to 1056 m²/h
up to 1344 m²/h
up to 1632 m²/h
up to 1090 m²/h
up to 1350 m²/h
up to 1600 m²/h
7. Noise and vibration data
The following noise and vibration data according to EC Machinery Directive in the version (2006/42/EC), was determined, taking into account the
following standards and directives. In operational use, values can deviate depending on the prevailing conditions.
7.1 Noise data
1)
The noise data specified in Appendix 1, sub-clause 1.7.4.u of the EC Machinery Directive is for:
Sound pressure level at the workplace L
PA
95,0 dB 93,3 dB
Measured sound power level L
WA,m
107 dB
Guaranteed sound power level L
WA,g
109 dB
The noise values were determined, taking into account the following directives and standards:
Directive 2000/14/EC / EN ISO 3744 / EN 500-4
7.2 Vibration data
Hand/arm vibration values according to Appendix 1, sub-clause 3.6.3.1 of the EC Machinery Directive:
Total vibration value of the acceleration a
hv
6.4 m/s
2
8.4 m/s
2
Uncertainty K 1.0 m/s
2
The acceleration value was determined, taking into account the following directives and standards:
EN 500-4 / DIN EN ISO 5349
2. Technical data
32
1)
As the permissible rating sound level of 85 dB (A) can be exceeded by this machine, operators must wear hearing protectors.

Table of Contents