43
Electric Actuator
OMMGGE00217 Rev 4 – MAY 2019
9 Energise the actuator power supply and control circuits and check for
correct operation.
4.9.2 Lubrication
To enable the actuator to be mounted in any position, a totally sealed and
permanently lubricated gear case is used. During long periods of storage, it is
not unusual for a very small amount of lubricant to weep from shaft seals. In
this event, wipe up the weeping lubricant with a clean cloth. During operation,
the weeping should disappear.
4.9.3 Sensor Mounting Bracket replacement
Refer to Fig 15.
Fig 15 Sensor Mounting Bracket replacement
Remove Sensor Mounting Bracket
1 Loosen the socket head cap screws and carefully lift off the Actuator
cover.