Page 3
FIREFINDER SERIES II INSTALLATION, COMMISSIONING &
OPERATION
2.1 FACP Configuration Examples
MAIN CONTROL CARD
20 WAY
10 WAY
FRONT PANEL CONTROL
CN3
CN21
CN20
TH1
CN8
CN1
CN6
D14
CN3
C12
BZ1
CN5
CN2
CN7
CN11
CH6 CH8
CH2
CH1
CN16
CN14
CN18
R17
TP3
CN4
CN10
CN15
CN13
CN17
c
ba
4 3 2
BRIG ADE I/F
FRO NT PA NELEXPAN SION LE DS
EXPAN SION PAN EL
MOD EM
27V IN
PRIN TER
PSU MON ITOR
LOOP COM MS
1
+
ENSURE CN13 - 15 ARE FITTED
WITH PIN ENTRY SIDE FACING
THE BOTTOM OF THE BOARD
3 WAY
CN1
CN2
1
SLAVE CPU
CH8
CN1
CN2
1
CH8
CN1
CN2
1
RJ45
SLAVE CPU
SLAVE CPU
U15
CN2
a b
c
U11
U10
U14
U13
CPU BOARD
PRINTER PSU
C/W CAB2153
3 WAY
26 WAY
5V
OUT
CN 1
HY 1
CN2
27v
In
- +
- +
PRINTER
(OEM1447)
CN3
10 WAY
PRINTER MOUNTING BRACKET
+ -+ -
+ -
AUXILIARY
+ BAT -+ IN -
DBA/MCP
DOOR SW
BELL2BELL1
FAULTVALVE MON
BATT FAIL
NO C NC
NO C NC NO C NC
NO C NC
NO C NC+ - + - NO C NC
+ -
+ -
ALARM ISOLATE
C
SGD II
WARN SYSAUX POW ER O/P
TB10
CN3
TB4
CN2
CN1
TB6
TB5
CN6
TB3
CN5
TB2
BRIGADE PSU
MONITOR
BOARD
EARTH
STUD
FUSE BLOCK
MAINS
INPUT
POWER
SUPPLY
UNIT
CN1CN3
2 LOOP TERMINATION BOARD OR
16Z CONVENTIONAL BOARD
L2+ L1-
B
L2+ L1-
A EXT
+35V
EXT
+35V
L2+ L1-
B
L2+ L1-
A EXT
+35V
EXT
+35V
EXTERNAL
CONTROL
INTERFACE
BOARD
MOUNTED
ABOVE
POW ER
CN4
CN2
TX1
6 WAY
4 WAY
FRONT DOOR AND FRONT INNER DOOR
REAR VIEW SHOWING INSTALLED BOARDS
ON FRONT INNER DOOR AND WIRING DETAILS
CABINET BACKPAN VIEW SHOWING MODULES
FITTED TO THE BACKPAN AND WIRING DETAILS
TO BATTERIES
OPTIONAL NETWORKING BOARDS
NETWORK INTERFACE CARD
HLI CONTROLLER CARD.
NOTE: POSITION MAY VARY AS SHOWN
AND IS FOR INDICATION ONLY.
GENERAL INDICATOR
CARD
ON
1 2 3 4 5 6 7 8
HLI
CONTROLLER
LSB
FACP
COMM S
EOL
EOL
RS485
SER IAL
PARA LL EL
+27V
RS4 85
ADD R ESS
0V
0V +27V
SHD
-
+
SHD
-
+
-
FACP
FACP 0V
SHD
+
POWE R
COMM S
MSB
+
-
D6
ZDN 2
C74
U8
TB1
1 2 3 4
SW1
CN2
TB3
CN4
CN8
D7
LK2
LK3
CN5
16 WAY
NETWORK I/F
BOARD
CPU
CN5
CN1
CN2CN3
CN4
CN7
CN8
TB 1
TB 2
TB 3
U13
U14
U10
U11
c
ba
CN2
U15
+
-
S HD
+
-
S HD
ACTIVE
NEUTRAL
GROUND
-VE
+VE
L(AC) N(AC)
-V -V +V +V
(AC)
FUSE BLOCK
ACTIVE
BROWN
EARTH
GREEN
NEUTRAL
BLUE
NOTE1: WIRING MAY VARY DEPENDING ON PANEL CONFIGURATION
NOTE2: AN EXTERNAL BATTERY CABINET WILL BE REQUIRED IF THE FACP IS FULLY OPTIONED
TYPICAL LAYOUT FOR A FULLY POPULATED BACKPAN:
X- 2 LOOP TERMINATION BOARD OR
X-16 ZONE CONVENTIONAL BOARD
X- BRIGADE PSU MONITOR BOARD
X- POWER SUPPLY UNIT (KIT 2 AMP = 330-0018 SINGAPORE) OR
X- POWER SUPPLY UNIT (KIT 5 AMP = 330-0021 MALAYSIA)
X- EXTERNAL CONTROL INTERFACE (KIT 159-0094)
REFER TO MANUAL FOR TERMINATIONS
TYPICAL LAYOUT FOR A FULLY POPULATED FRONT PANEL:
X- MAF (341-0015) CONSISTS OF:
1- CONTROL PANEL
1- MAIN CONTROL CARD
1- MAIN CPU
X-SLAVE CPU
X- EXPANSION BOARD
X- PRINTER (OEM1447) C/W MOUNTING PLATE. (KIT = 159-0093)
X- GENERAL INDICATOR CARD 32 RED LED. (KIT 159-0089)
REFER TO MANUAL FOR TERMINATIONS
KEYHOLE MOUNTING HOLE
Figure 2: Typical Example of a CP10-1 Layout

Table of Contents

Other manuals for Ampac FireFinder II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ampac FireFinder II Series and is the answer not in the manual?

Ampac FireFinder II Series Specifications

General IconGeneral
BrandAmpac
ModelFireFinder II Series
CategoryFire Alarms
LanguageEnglish

Related product manuals