Page 81
FireFinder
TM
Quick Reference
FUNCTION KEY ( TO ENTER FUNCTION FIELD ( ENTER PASSWORD ) )
PROG ( PROGRAMMING FEILDS )
EDIT ( EDIT DESCRIPTION )
DELETE ( LOOP / SENSOR )
IN A PANEL
( SELECT INPUT CONTROL No AND INPUT No )
EDIT ( EDIT DESCRIPTION )
CON ZONE ( EDIT ZONE NUMBER, DESCRIPTION )
INPUT ( EDIT INPUT FIELDS )
EDIT ( DESCRIPTION, ZONE No,
DEVICE TYPE, BRIGADE OPTIONS,
CONFIGURATION, GROUP No )
DELETE ( DELETE DESCRIPTION )
ON A LOOP ( LOOP / SENSOR No )
DEVICE ( ENTER LOOP / SENSOR )
DELETE ( DELETE DESCRIPTION )
IN A PANEL
( SELECT OUTPUT CONTROL No AND OUTPUT No )
OUTPUT ( EDIT OUTPUT FIELDS )
ON A LOOP ( LOOP / SENSOR No )
PASSWORDS ( EDIT PASSWORD FIELDS )
ADD PASSWORD ( ADD PASSWORD (MAX 4 CHAR), LEVEL No )
DELETE PASSWORD ( DELETE SELECTED PASSWORD )
DELETE ALL PASSWORDS ( DELETE ALL PASSWORDS )
LEVEL 2 FUNCTION
FUNCTION KEY ( TO ENTER FUNCTION FIELD ( ENTER PASSWORD ) )
I/O ( MANUAL INPUT /OUTPUT CONTROL FIELDS )
OFF ( TURN INPUT OFF )
ON ( TURN INPUT ON )
ON A LOOP
( SELECT LOOP No, SENSOR No, INPUT No )
REMOVE ALL MANUAL INPUT CONTROL
( RETURN ALL MANUAL INPUTS TO ORIGINAL STATE )
INPUT ( INPUT FIELDS )
IN A PANEL
( SELECT I/O CONTROL NUMBER AND INPUT No )
REMOVE MANUAL CONTROL
( RETURN INPUT TO
ORIGINAL STATE)
OFF ( TURN INPUT OFF )
ON ( TURN INPUT ON )
REMOVE MANUAL CONTROL
( RETURN INPUT TO
ORIGINAL STATE)
OFF ( TURN OUTPUT OFF )
ON ( TURN OUTPUT ON )
ON A LOOP
( SELECT LOOP No, SENSOR No, OUTPUT No )
GLOBAL REMOVE ALL MANUAL OUTPUT CONTROL
( RETURN ALL MANUAL O/PS TO ORIGINAL STATE )
OUTPUT ( OUTPUT FIELDS )
IN A PANEL
( SELECT I/O CONTROL NUMBER AND OUTPUT No )
REMOVE MANUAL CONTROL
( RETURN OUTPUT TO
ORIGINAL STATE)
OFF ( TURN OUTPUT OFF )
ON ( TURN OUTPUT ON )
REMOVE MANUAL CONTROL
( RETURN OUTPUT TO
ORIGINAL STATE)
LEVEL 2
FUNCTIONS
FUNCTION MENU OPTIONS
FUNCTION KEY ( TO ENTER FUNCTION FIELD ( ENTER PASSWORD ) )
DATE ( DD/MM/YYYY )
TIME ( HH:MM )
DAY/NIGHT SETTINGS ( SET ON/OFF FIELDS )
DAY TIME (HH:MM)
ENABLE
LOGS
LEVEL 1
FUNCTIONS
NIGHT TIME (HH:MM)
ALARM ( ALARM LOG )
SHOW OPTIONS
VIEW BY ENTRY NO.
VIEW BY DATE
PRINT ENTRY (PRINT TO PANEL PRINTER (IF FITTED))
FAULT ( FAULT LOG )
ISOLATE ( ISOLATE LOG )
WALK ( ZONES OR SENSORS )
TESTS ( TEST SPECIFIED FIELD )
ZONE ( ENTER ZONE No )
SENSOR ( ENTER LOOP / SENSOR No )
LOOP ( ENTER LOOP No )
PQRS
6
SPACE
0
ABC
1
SPACE
0
SPACE
0
ABC
1
DEF
2
ABC
1
ABC
1
SPACE
0
ABC
1
SPACE
0
ABC
1
GHI
3
SPACE
0
TUV
7
SPACE
0
ABC
1
DEF
2
MENU
FUNCTION
MNO
5
SPACE
0
SPACE
0
ABC
1
DEF
2
ABC
1
SPACE
0
SPACE
0
ABC
1
DEF
2
SPACE
0
SPACE
0
ABC
1
DEF
2
ABC
1
SPACE
0
ABC
1
DEF
2
ABC
1
DEF
2
DEF
2
MENU
FUNCTION
SPACE
0
DEF
2
ABC
1
SPACE
0
ABC
1
GHI
3
MENU
FUNCTION
2
DEF
SPACE
0
SPACE
0
ABC
1
SPACE
0
ABC
1
DEF
2
1
ABC
JKL
4
SPACE
0
SPACE
0
ABC
1
ABC
1
PANEL BASED MCP ( DESCRIPTION / NODE )
JKL
4
SUB ADDRESS ( EDIT / DELETE )
MNO
5
WATCHDOG RESET
PQRS
6
PRINT MULTIPLE ENTRIES
2
DEF
SYSTEM ( SYSTEM LOG )
DEF
3
AS FOR ALARM
AS FOR ALARM
AS FOR ALARM
JKL
4
AS FOR ALARM
I/O (INPUT / OUTPUT LOG )
AS FOR INPUT
AS FOR INPUT
GHI
3
MODE ZONE / SENSOR
DISABLED IF FACP
IS NETWORKED
ACCESS LEVEL 3 ( ENTER LEVEL 3 PASSWORD )
PQRS
6
LEVEL 3 FUNCTION

Table of Contents

Other manuals for Ampac FireFinder II Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ampac FireFinder II Series and is the answer not in the manual?

Ampac FireFinder II Series Specifications

General IconGeneral
BrandAmpac
ModelFireFinder II Series
CategoryFire Alarms
LanguageEnglish

Related product manuals