Non-Contact Voltage Detection (NCV Mode)

1. To avoid personal injury or damage to the Meter, do not test on un-
insulated high voltage wires.
2. Buzzer will sound and screen will display “OL” when detecting ac
Voltage above 90V ac.
3. Do not test on hazardous live wires higher than 750V ac.
4. Before and after hazardous voltage measurements, test the Meter by
approaching to a known source such as a line ac Voltage or outlet to
determine proper operation.
5. At NCV mode, no test lead connections are required for NCV measurement.
Buzzer will sound when the detected voltage is ≥90V, and the buzzer will be
on. The distances between the wire and the meter should be ≤8mm.