Trouble shooting
Fault
Check
Action
Motor stops and the light in
the motor control switch
flashes
The motor has reached the max load limit
Release the button and run the winch with
less load
The motor circuit has reached max
temperature, which is app 60°C
When the temperature falls within the
accepted range, the motor will function
normally. Let the motor cool off till its
ready to operate again
The flashing light in the motor control
switch indicates that the winch has been
running for more than
4¼ minute
Release the button and start over again.
Check that the motor control switch cable is
not damaged or worn
Replace cable is necessary
The motor does not run,
there is no light in the
motor control switch
Check that the circuit breaker and main
power switch are in the “ON” position
If “OFF” turn “ON”
Check the voltage supply at the motor
Check terminal connections
Check that the motor control switch is
connected to the motor
Connect the switch
The motor does not run
when activating the motor
control switch but there’s
light in the switch
Check that the voltage supply to the motor
terminals is correct
When the correct voltage is available, the
motor function shall be normal
Check that the switch cable is not worn or
damaged in any place
Replace cable if possible
The circuit breaker trips
straight away after being
reset
Error code on the circuit breaker, see
chapter: Circuit breaker safety switch
information codes
Depending on the error code action has to
be taken.
Check that the voltage at the breaker is
correct
Charge or change battery
Check terminal connections
When the correct voltage is available, the
breaker can be reset
Check the connections and wiring from the
motor thermo sensor to the circuit breaker
printed circuit board
If the thermo-sensor is not connected the
breaker will trip. Re-connect the wire and
replace if damaged
Check that the motor hasn’t overheated. If
over 70ºC the motor thermo sensor will turn
the circuit breaker “OFF”
When the motor cools the circuit breaker
can be re-set. If the problem re-occurs
contact your Andersen dealer for service.
The circuit breaker trips
when using the winch
Error code on the circuit breaker, see
chapter: Circuit breaker safety switch
information codes
Depending on the error code action has to
be taken.
There is no light or flashing
in the green diode on the
back of the circuit breaker
when it is switched “ON”
When there is no light from the circuit
breaker important safety features will not
function. Check that the “MINUS” supply
to the circuit board is not broken or
damaged.
Reattach the “MINUS” wire to the minus
terminal on the print
The printed circuit board on the breaker
can be damaged, replace it with a new
print circuit board.
The circuit breaker trips
and no error code is present
on the diodes
The current consumption is higher than the
rated current consumption on the circuit
breaker, therefore it cuts off
Check the installation for faults
Below-Deck Only:
Water drips from drain
holes near base of through-
deck extension tube.
Water ingress at output gear shaft seal.
Perform recommended lubrication of seal,
or replace seal if necessary.