[Procedure using remote commands]
1. Execute PRESET to set default parameter.
2. Execute CALLPROC ON to set Common Parameter Call Processing to On.
3. Execute CHCODING PACKET_DL_CA_PCC to set Common Parameter Signal Channel Coding to
Packet (DL CA).
4. Execute ANTCONFIG OPEN_LOOP to set Common Parameter Signal Antenna Configuration to
2x2MIMO (Open Loop).
5. Execute UECAT CAT9 set Common Parameter Signal UE Category to 9.
(When 4DL CA, Execute UECAT CAT11 set Common Parameter Signal UE Category to 11.)
6. Execute DLSCC 2 to set Call Processing Parameter Carrier Aggregation Number of DL SCC to 2.
(When 4DL CA, Execute DLSCC 3 to set Call Processing Parameter Carrier Aggregation Number of
DL SCC to 3.)
7. Execute BANDWIDTH 20MHZ to set Common Parameter Frequency Channel Bandwidth to 20 MHz.
8. Execute DLCHAN 300 to set Common Parameter - Frequency UL Channel and DL Channel to 18300
and 300, respectively.
9. Execute OLVL_EPRE -70.0 to set Common Parameter Level Output Level(EPRE) to 70.0 dBm/15
kHz.
10. Execute ULRMC_RB 100 to set Common Parameter UL RMC Number of RB to 100.
11. Execute ULIMCS 23 to set Common Parameter UL RMC MCS Index to 23.
12. Execute DLRB 100,0 to set Common Parameter DL RMC Number of RB to 100, and Common
Parameter DL RMC Starting RB to 0.
13. Execute BANDWIDTH_SCC1 20MHZ to set Common Parameter SCC1 Channel Bandwidth to 20 MHz.
14. Execute DLIMCS1 28, DLIMCS2 28 and DLIMCS3 28 to set All of Common Parameter DL RMC MCS
Index1/2/3 to 28.
15. Execute DLCHAN_SCC1 498 to set Common Parameter SCC1 DL Channel to 498.
16. Execute OLVL_EPRE_SCC1 -70.0 to set Common Parameter SCC-1 Output Level(EPRE) to 70.0 dBm/15
kHz.
17. Execute DLRB_SCC1 100,0 to set Common Parameter SCC1 DL RMC - Number of RB to 100, and
Common Parameter SCC1 DL RMC Starting RB to 0.
18. Execute DLIMCS1_SCC1 28, DLIMCS2_SCC1 28 and DLIMCS3_SCC1 28 to set All of Common Parameter
SCC1 DL RMC MCS Index1/2/3 to 28.
19. Execute BANDWIDTH_SCC2 20MHZ to set Common Parameter SCC2 Channel Bandwidth to 20 MHz.
20. Execute DLCHAN_SCC2 1575 to set Common Parameter SCC2 DL Channel to 1575.
21. Execute OLVL_EPRE_SCC2 -70.0 to set Common Parameter SCC-2 Output Level(EPRE) to 70.0 dBm/15
kHz.
22. Execute DLRB_SCC2 100,0 to set Common Parameter SCC2 DL RMC - Number of RB to 100, and
Common Parameter SCC2 DL RMC Starting RB to 0.
23. Execute DLIMCS1_SCC2 28, DLIMCS2_SCC2 28 and DLIMCS3_SCC2 28 to set All of Common Parameter -
SCC2 DL RMC MCS Index1/2/3 to 28.
When 4DL CA, execute 24 to 28
24. Execute BANDWIDTH_SCC3 20MHZ to set Common Parameter SCC3 Channel Bandwidth to 20 MHz.
25. Execute DLCHAN_SCC3 1773 to set Common Parameter SCC3 DL Channel to 1575.
26. Execute OLVL_EPRE_SCC3 -70.0 to set Common Parameter SCC3 Output Level(EPRE) to 70.0 dBm/15
kHz.
27. Execute DLRB_SCC3 100,0 to set Common Parameter SCC3 DL RMC - Number of RB to 100, and
Common Parameter SCC3 DL RMC Starting RB to 0.
28. Execute DLIMCS1_SCC2 28, DLIMCS2_SCC2 28 and DLIMCS3_SCC2 28 to set All of Common Parameter -
SCC2 DL RMC MCS Index1/2/3 to 28.
29. Execute SERVERIP 192,168,20,10 to set Call Processing Parameter - Packet - Server IP Address to
192.168.20.10.
30. Execute CLIENTIP 192,168,20,11 to set Call Processing Parameter - Packet - Client IP Address 1 to
192.168.20.11.
31. Execute CLIENTIP2 192,168,20,12 to set Call Processing Parameter - Packet - Client IP Address 2 to
192.168.20.12.
32. Execute DEDEPSACT ON to set Call Processing Parameter - Packet - Dedicated EPS Bearer Activation to On.

Table of Contents

Other manuals for Anritsu MT8821C

Related product manuals