Chapter 4 — Spectrum Analyzer Commands 4-12 :TRIGger Subsystem
MS2720T PM PN: 10580-00341 Rev. C 4-47
:TRIGger[:SEQuence]:VIDeo:LEVel <amplitude>
:TRIGger[:SEQuence]:VIDeo:LEVel?
Title: Video Trigger Level
Description: This command sets the video triggering level.
Parameter: <amplitude>
Default Value: –65.0 dBm
Default Unit: Current amplitude unit
Range: 30 dBm to –150 dBm
Front Panel
Access: Shift-3 (Sweep), Triggering, Level
:TRIGger[:SEQuence]:VIDeo:POSition <percentage>
:TRIGger[:SEQuence]:VIDeo:POSition?
Title: Video Trigger Position
Description: This command sets the video triggering position as a percentage of the
display. When the sweep is triggered, the trigger point is drawn at the
location defined by the position. The graph appearing to the left of the
trigger position is data acquired before the trigger. The graph appearing
to the right of the trigger position is data acquired after the trigger.
Parameter: <percentage>
Default Value: 1
Default Unit: %
Range: 0% to 100%
Front Panel
Access: Shift-3 (Sweep), Triggering, Delay