15-7 [:SENSe] Subsystem Chapter 15 — AM/FM/PM Commands
15-14 PN: 10580-00341 Rev. C MS2720T PM
15-7 [:SENSe] Subsystem
The commands in this subsystem relate to device-specific parameters, not signal-oriented
parameters.
[:SENSe]:AFPanalyzer:AVERage:COUNt <avg count>
[:SENSe]:AFPanalyzer:AVERage:COUNt?
Title: Measurement Average
Description: Sets the average count for the measurement data in the summary mode.
The query format of this command returns the value only in the
summary mode. The query format returns nothing in other
measurement modes.
Parameter: <number>
Range: 1 to 65535
Front Panel
Access: Shift-4 (Measure), Average (only in Summary mode)
[:SENSe]:AFPanalyzer:DEMod:DATA?
Title: Summary data
Description: This query returns the measurement values in the Summary view. The
order of the values are as follows:
<Modulation rate> in Hz, <RMS Deviation> in % or Hz or Rad
depending on the demod type, <Peak-Peak/2 Dev> in % or Hz or Rad
depending on the demod type, <SINAD> in dB, <THD> in % and
<Distortion> in %. All values are comma separated.
Front Panel
Access: Shift-4 (Measure), Audio Spectrum/Waveform.
[:SENSe]:AFPanalyzer:DEMod:MODE RFSP|AFSP|AFWV|SUMMary
[:SENSe]:AFPanalyzer:DEMod:MODE?
Title: Demodulation Mode
Description: This command sets the demodulation mode (graph type) to RF
spectrum (RFSP) or Audio Spectrum (AFSP) or Audio
Waveform (AFWV) or Summary.
Parameter: RFSP|AFSP|AFWV|SUMMary
Default Value: RFSP
Example: To set the demodulation mode to Audio Waveform:
SENSe:AFPanalyzer:DEMod:MODE AFWV
Front Panel
Access: Shift-4 (Measure).
ООО "Техэнком" Контрольно-измерительные приборы и оборудование www.tehencom.com