Parameter adjustment range
Model
Item
Welding current (A)
Arc force current (A)
WY-315
20-315
0-160
WY-400
20-400
0-200
WY-500
20-500
0-250
WY-630
20-630
0-250
Table 11-2-1: Parameter adjustment range
Operating guide
1.Set the control mode at ā€œRemote controlā€;
2.Attach the remote controller to the work piece, and ensure good contact;
3.Connect the clamp with electrode holder to supply power to remote controller;
4.The digital displayer shows the current value; adjust the welding current and arc force current in accordance
with the welding requirements;
5.Remove the clamp from the electrode holder or remove remote controller from work piece when complete the
regulation, and be ready for welding.
Important:
Ensure the remote controller is grounded well, and the clamp connect with electrode holder tightly;
Avoid electrode holder contacting with remote controller and cause sparking;
Avoid contacting work piece when clamp connects electrode holder tightly;
Avoid impacting the remote controller and cause deformation.