AP Diving Ltd. Medium Pressure and Convoluted Hose Shortening Instructions
Page 21 of 38
4.5 Screw the shortened MP hose back into the hose collar
WARNING: This has a Left Hand Thread, so in order to screw the hose in the hose
collar, you need to screw anti-clock-wise, NOT clock-wise!
- Using a 17 mm spanner, screw the hose collar onto the MP hose.
- Screw anti-clock-wise.
- Screw the hose in until the hose JUST touches the shoulder on the inside of the hose
collar.
- Once it touches the shoulder, back the hose out (i.e. unscrew) half a turn, clock-wise.