990-2404A 04/2008
Smart-UPS
®
XL
Uninterruptible Power Supply
Rack-Mount 3U
SUA2200/3000 VA 120/230 Vac
SUA3000 VA 100/200 Vac
English
Question and Answer IconNeed help?

Do you have a question about the APC SUA2200 and is the answer not in the manual?

Summary

Introduction

About this UPS

Explains the function of the APC Uninterruptible Power Supply (UPS) for electronic equipment protection.

Accessories

Details the UPS accessories and the SmartSlot feature for expansion.

Unpack

Instructions for unpacking the UPS, checking contents, and handling packaging.

Specifications

Environmental

Specifies operating and storage temperature, humidity, and elevation limits for the UPS.

Physical

Provides physical dimensions, weight, and external battery pack support.

Electrical

Lists output and input voltage, and frequency specifications for different models.

Installation

Install the Rails in the Rack

Instructions for installing the UPS rails into a 19-inch rack.

Install the UPS in the Rack and Connect the Battery Module

Steps for physically mounting the UPS in the rack and connecting the battery module.

Rear Panels

Details the rear panel layout and features of different UPS models.

Rear Panel Features

Describes specific features on the rear panel, like TVSS screw, EPO, SmartSlot, etc.

Start-up and Operation

Connect equipment, external battery pack(s), and power to the UPS

Guides on connecting external equipment, battery packs, and powering the UPS.

Start the UPS

Instructions on how to power on the UPS and initial battery charging behavior.

Display Panels

Shows the front panel displays for 120 V and 100/200/230 V models.

Display Panel Indicators and Function Buttons

Explains the meaning of each indicator LED and function button on the UPS front panel.

Diagnostic Utility Voltage

Describes the diagnostic feature to check utility voltage using the UPS display.

Feature Buttons

Details the functions of Power On, Power Off, Self-Test, and Cold Start buttons.

Configuration

UPS settings

Explains how to adjust UPS settings like Auto Self-Test, UPS ID, and sensitivity.

Low Battery Warning

Configures the low battery warning interval and relates it to safe shutdown.

Synchronized Turn-on Delay

Sets the delay before the UPS starts up after utility power returns, avoiding overload.

High Transfer Point

Adjusts the voltage threshold for transferring to battery power due to high utility voltage.

Low Transfer Point

Adjusts the voltage threshold for transferring to battery power due to low utility voltage.

Output Voltage

Sets the output voltage for specific 230 V models.

Connect the Emergency Power Off option

Explains how to connect and wire the Emergency Power Off (EPO) feature.

Configure UPS parameters

Explains how to configure UPS to recognize external battery packs.

Configure UPS connection settings using NMC terminal mode

Steps for connecting and configuring the UPS via NMC terminal mode.

Configure UPS connection settings using UPS terminal mode

Steps for connecting and configuring the UPS via standard UPS terminal mode.

Configure the number of external battery packs using UPS terminal mode

Instructions on setting the number of external battery packs via UPS terminal mode.

Maintenance, Transport, and Service

Replacing the Battery Module

Instructions and precautions for safely replacing the UPS battery module.

Service

Steps to follow if the UPS requires service, including contacting customer support.

Troubleshooting

UPS will not turn on

Solutions for the UPS failing to power on, checking connections and buttons.

UPS will not turn off

Addresses the UPS not turning off, suggesting an internal fault.

UPS beeps occasionally

Explains occasional beeps, often related to normal operation or alarms.

UPS is not providing expected backup time

Troubleshooting for insufficient battery backup time, checking battery health.

All LEDs are illuminated and the UPS emits a constant beeping

Solutions for when all LEDs are on and the UPS beeps constantly, indicating an internal fault.

The Disconnected Battery; Replace Battery LED is illuminated

Explains the meaning of the Disconnected Battery/Replace Battery LED and related issues.

The Site Wiring Fault LED on the rear panel is illuminated (120 V models only)

Addresses the Site Wiring Fault LED, indicating utility wiring problems.

The input circuit breaker trips

Troubleshooting steps for when the UPS input circuit breaker trips.

The AVR Boost or AVR Trim LEDs are illuminated

Explains illuminated AVR LEDs indicating voltage fluctuations.

There is no utility power

Solutions for when there is no utility power and the UPS is off.

UPS operates on battery although line voltage exists

Addresses the UPS running on battery despite available line voltage.

Battery Charge and Load LEDs flash simultaneously

Explains simultaneous flashing of Battery Charge and Load LEDs, indicating shutdown due to internal temperature.

Diagnostic utility voltage

Interprets the diagnostic utility voltage indicators on the UPS.

On Line LED

Explains the status of the On Line LED (no illumination or blinking).

Regulatory and Warranty Information

Regulatory Agency Approvals and Radio Frequency Warnings

Lists regulatory approvals and FCC compliance notices for the UPS models.

Two-Year Limited Warranty

Terms of warranty

Outlines the terms, conditions, and exclusions of the limited factory warranty.

Warranty claims

Provides information on how to submit warranty claims and contact customer support.

EC Declaration of Conformity

Harmonized Standards

Lists the harmonized standards and directives the equipment conforms to.

Applicable Council Directives

Specifies the council directives that the equipment complies with.

Type of Equipment

Identifies the type of equipment as an Uninterruptible Power Supply.

Model Numbers

Lists the specific model numbers for the UPS units.

Manufacturers

Lists the various manufacturing locations for the APC product.

APC Worldwide Customer Support

Customer support

Details how to access customer support and resources via the APC website and contact centers.

Summary

Introduction

About this UPS

Explains the function of the APC Uninterruptible Power Supply (UPS) for electronic equipment protection.

Accessories

Details the UPS accessories and the SmartSlot feature for expansion.

Unpack

Instructions for unpacking the UPS, checking contents, and handling packaging.

Specifications

Environmental

Specifies operating and storage temperature, humidity, and elevation limits for the UPS.

Physical

Provides physical dimensions, weight, and external battery pack support.

Electrical

Lists output and input voltage, and frequency specifications for different models.

Installation

Install the Rails in the Rack

Instructions for installing the UPS rails into a 19-inch rack.

Install the UPS in the Rack and Connect the Battery Module

Steps for physically mounting the UPS in the rack and connecting the battery module.

Rear Panels

Details the rear panel layout and features of different UPS models.

Rear Panel Features

Describes specific features on the rear panel, like TVSS screw, EPO, SmartSlot, etc.

Start-up and Operation

Connect equipment, external battery pack(s), and power to the UPS

Guides on connecting external equipment, battery packs, and powering the UPS.

Start the UPS

Instructions on how to power on the UPS and initial battery charging behavior.

Display Panels

Shows the front panel displays for 120 V and 100/200/230 V models.

Display Panel Indicators and Function Buttons

Explains the meaning of each indicator LED and function button on the UPS front panel.

Diagnostic Utility Voltage

Describes the diagnostic feature to check utility voltage using the UPS display.

Feature Buttons

Details the functions of Power On, Power Off, Self-Test, and Cold Start buttons.

Configuration

UPS settings

Explains how to adjust UPS settings like Auto Self-Test, UPS ID, and sensitivity.

Low Battery Warning

Configures the low battery warning interval and relates it to safe shutdown.

Synchronized Turn-on Delay

Sets the delay before the UPS starts up after utility power returns, avoiding overload.

High Transfer Point

Adjusts the voltage threshold for transferring to battery power due to high utility voltage.

Low Transfer Point

Adjusts the voltage threshold for transferring to battery power due to low utility voltage.

Output Voltage

Sets the output voltage for specific 230 V models.

Connect the Emergency Power Off option

Explains how to connect and wire the Emergency Power Off (EPO) feature.

Configure UPS parameters

Explains how to configure UPS to recognize external battery packs.

Configure UPS connection settings using NMC terminal mode

Steps for connecting and configuring the UPS via NMC terminal mode.

Configure UPS connection settings using UPS terminal mode

Steps for connecting and configuring the UPS via standard UPS terminal mode.

Configure the number of external battery packs using UPS terminal mode

Instructions on setting the number of external battery packs via UPS terminal mode.

Maintenance, Transport, and Service

Replacing the Battery Module

Instructions and precautions for safely replacing the UPS battery module.

Service

Steps to follow if the UPS requires service, including contacting customer support.

Troubleshooting

UPS will not turn on

Solutions for the UPS failing to power on, checking connections and buttons.

UPS will not turn off

Addresses the UPS not turning off, suggesting an internal fault.

UPS beeps occasionally

Explains occasional beeps, often related to normal operation or alarms.

UPS is not providing expected backup time

Troubleshooting for insufficient battery backup time, checking battery health.

All LEDs are illuminated and the UPS emits a constant beeping

Solutions for when all LEDs are on and the UPS beeps constantly, indicating an internal fault.

The Disconnected Battery; Replace Battery LED is illuminated

Explains the meaning of the Disconnected Battery/Replace Battery LED and related issues.

The Site Wiring Fault LED on the rear panel is illuminated (120 V models only)

Addresses the Site Wiring Fault LED, indicating utility wiring problems.

The input circuit breaker trips

Troubleshooting steps for when the UPS input circuit breaker trips.

The AVR Boost or AVR Trim LEDs are illuminated

Explains illuminated AVR LEDs indicating voltage fluctuations.

There is no utility power

Solutions for when there is no utility power and the UPS is off.

UPS operates on battery although line voltage exists

Addresses the UPS running on battery despite available line voltage.

Battery Charge and Load LEDs flash simultaneously

Explains simultaneous flashing of Battery Charge and Load LEDs, indicating shutdown due to internal temperature.

Diagnostic utility voltage

Interprets the diagnostic utility voltage indicators on the UPS.

On Line LED

Explains the status of the On Line LED (no illumination or blinking).

Regulatory and Warranty Information

Regulatory Agency Approvals and Radio Frequency Warnings

Lists regulatory approvals and FCC compliance notices for the UPS models.

Two-Year Limited Warranty

Terms of warranty

Outlines the terms, conditions, and exclusions of the limited factory warranty.

Warranty claims

Provides information on how to submit warranty claims and contact customer support.

EC Declaration of Conformity

Harmonized Standards

Lists the harmonized standards and directives the equipment conforms to.

Applicable Council Directives

Specifies the council directives that the equipment complies with.

Type of Equipment

Identifies the type of equipment as an Uninterruptible Power Supply.

Model Numbers

Lists the specific model numbers for the UPS units.

Manufacturers

Lists the various manufacturing locations for the APC product.

APC Worldwide Customer Support

Customer support

Details how to access customer support and resources via the APC website and contact centers.

APC SUA2200 Specifications

General IconGeneral
Power Capacity2200 VA / 1980 W
Nominal Output Voltage230V
Nominal Input Voltage230V
Typical Recharge Time8 hours
Input Connection TypeIEC 320 C14
Interface PortUSB, Serial
Audible AlarmYes
Waveform TypeSine wave
Operating Temperature0°C to 40°C
Storage Temperature-15°C to 45°C
Output Frequency50/60 Hz
Battery TypeLead-acid battery
Control PanelLED status display with On Line, On Battery, Replace Battery and Overload indicators
Transfer Time4 ms typical
Humidity0-95% non-condensing
DisplayLED status indicators
TypeLine Interactive
Number of Outlets8