Do you have a question about the APC SUA2200 and is the answer not in the manual?
Explains the function of the APC Uninterruptible Power Supply (UPS) for electronic equipment protection.
Details the UPS accessories and the SmartSlot feature for expansion.
Instructions for unpacking the UPS, checking contents, and handling packaging.
Specifies operating and storage temperature, humidity, and elevation limits for the UPS.
Provides physical dimensions, weight, and external battery pack support.
Lists output and input voltage, and frequency specifications for different models.
Instructions for installing the UPS rails into a 19-inch rack.
Steps for physically mounting the UPS in the rack and connecting the battery module.
Details the rear panel layout and features of different UPS models.
Describes specific features on the rear panel, like TVSS screw, EPO, SmartSlot, etc.
Guides on connecting external equipment, battery packs, and powering the UPS.
Instructions on how to power on the UPS and initial battery charging behavior.
Shows the front panel displays for 120 V and 100/200/230 V models.
Explains the meaning of each indicator LED and function button on the UPS front panel.
Describes the diagnostic feature to check utility voltage using the UPS display.
Details the functions of Power On, Power Off, Self-Test, and Cold Start buttons.
Explains how to adjust UPS settings like Auto Self-Test, UPS ID, and sensitivity.
Configures the low battery warning interval and relates it to safe shutdown.
Sets the delay before the UPS starts up after utility power returns, avoiding overload.
Adjusts the voltage threshold for transferring to battery power due to high utility voltage.
Adjusts the voltage threshold for transferring to battery power due to low utility voltage.
Sets the output voltage for specific 230 V models.
Explains how to connect and wire the Emergency Power Off (EPO) feature.
Explains how to configure UPS to recognize external battery packs.
Steps for connecting and configuring the UPS via NMC terminal mode.
Steps for connecting and configuring the UPS via standard UPS terminal mode.
Instructions on setting the number of external battery packs via UPS terminal mode.
Instructions and precautions for safely replacing the UPS battery module.
Steps to follow if the UPS requires service, including contacting customer support.
Solutions for the UPS failing to power on, checking connections and buttons.
Addresses the UPS not turning off, suggesting an internal fault.
Explains occasional beeps, often related to normal operation or alarms.
Troubleshooting for insufficient battery backup time, checking battery health.
Solutions for when all LEDs are on and the UPS beeps constantly, indicating an internal fault.
Explains the meaning of the Disconnected Battery/Replace Battery LED and related issues.
Addresses the Site Wiring Fault LED, indicating utility wiring problems.
Troubleshooting steps for when the UPS input circuit breaker trips.
Explains illuminated AVR LEDs indicating voltage fluctuations.
Solutions for when there is no utility power and the UPS is off.
Addresses the UPS running on battery despite available line voltage.
Explains simultaneous flashing of Battery Charge and Load LEDs, indicating shutdown due to internal temperature.
Interprets the diagnostic utility voltage indicators on the UPS.
Explains the status of the On Line LED (no illumination or blinking).
Lists regulatory approvals and FCC compliance notices for the UPS models.
Outlines the terms, conditions, and exclusions of the limited factory warranty.
Provides information on how to submit warranty claims and contact customer support.
Lists the harmonized standards and directives the equipment conforms to.
Specifies the council directives that the equipment complies with.
Identifies the type of equipment as an Uninterruptible Power Supply.
Lists the specific model numbers for the UPS units.
Lists the various manufacturing locations for the APC product.
Details how to access customer support and resources via the APC website and contact centers.
Explains the function of the APC Uninterruptible Power Supply (UPS) for electronic equipment protection.
Details the UPS accessories and the SmartSlot feature for expansion.
Instructions for unpacking the UPS, checking contents, and handling packaging.
Specifies operating and storage temperature, humidity, and elevation limits for the UPS.
Provides physical dimensions, weight, and external battery pack support.
Lists output and input voltage, and frequency specifications for different models.
Instructions for installing the UPS rails into a 19-inch rack.
Steps for physically mounting the UPS in the rack and connecting the battery module.
Details the rear panel layout and features of different UPS models.
Describes specific features on the rear panel, like TVSS screw, EPO, SmartSlot, etc.
Guides on connecting external equipment, battery packs, and powering the UPS.
Instructions on how to power on the UPS and initial battery charging behavior.
Shows the front panel displays for 120 V and 100/200/230 V models.
Explains the meaning of each indicator LED and function button on the UPS front panel.
Describes the diagnostic feature to check utility voltage using the UPS display.
Details the functions of Power On, Power Off, Self-Test, and Cold Start buttons.
Explains how to adjust UPS settings like Auto Self-Test, UPS ID, and sensitivity.
Configures the low battery warning interval and relates it to safe shutdown.
Sets the delay before the UPS starts up after utility power returns, avoiding overload.
Adjusts the voltage threshold for transferring to battery power due to high utility voltage.
Adjusts the voltage threshold for transferring to battery power due to low utility voltage.
Sets the output voltage for specific 230 V models.
Explains how to connect and wire the Emergency Power Off (EPO) feature.
Explains how to configure UPS to recognize external battery packs.
Steps for connecting and configuring the UPS via NMC terminal mode.
Steps for connecting and configuring the UPS via standard UPS terminal mode.
Instructions on setting the number of external battery packs via UPS terminal mode.
Instructions and precautions for safely replacing the UPS battery module.
Steps to follow if the UPS requires service, including contacting customer support.
Solutions for the UPS failing to power on, checking connections and buttons.
Addresses the UPS not turning off, suggesting an internal fault.
Explains occasional beeps, often related to normal operation or alarms.
Troubleshooting for insufficient battery backup time, checking battery health.
Solutions for when all LEDs are on and the UPS beeps constantly, indicating an internal fault.
Explains the meaning of the Disconnected Battery/Replace Battery LED and related issues.
Addresses the Site Wiring Fault LED, indicating utility wiring problems.
Troubleshooting steps for when the UPS input circuit breaker trips.
Explains illuminated AVR LEDs indicating voltage fluctuations.
Solutions for when there is no utility power and the UPS is off.
Addresses the UPS running on battery despite available line voltage.
Explains simultaneous flashing of Battery Charge and Load LEDs, indicating shutdown due to internal temperature.
Interprets the diagnostic utility voltage indicators on the UPS.
Explains the status of the On Line LED (no illumination or blinking).
Lists regulatory approvals and FCC compliance notices for the UPS models.
Outlines the terms, conditions, and exclusions of the limited factory warranty.
Provides information on how to submit warranty claims and contact customer support.
Lists the harmonized standards and directives the equipment conforms to.
Specifies the council directives that the equipment complies with.
Identifies the type of equipment as an Uninterruptible Power Supply.
Lists the specific model numbers for the UPS units.
Lists the various manufacturing locations for the APC product.
Details how to access customer support and resources via the APC website and contact centers.
| Power Capacity | 2200 VA / 1980 W |
|---|---|
| Nominal Output Voltage | 230V |
| Nominal Input Voltage | 230V |
| Typical Recharge Time | 8 hours |
| Input Connection Type | IEC 320 C14 |
| Interface Port | USB, Serial |
| Audible Alarm | Yes |
| Waveform Type | Sine wave |
| Operating Temperature | 0°C to 40°C |
| Storage Temperature | -15°C to 45°C |
| Output Frequency | 50/60 Hz |
| Battery Type | Lead-acid battery |
| Control Panel | LED status display with On Line, On Battery, Replace Battery and Overload indicators |
| Transfer Time | 4 ms typical |
| Humidity | 0-95% non-condensing |
| Display | LED status indicators |
| Type | Line Interactive |
| Number of Outlets | 8 |