General features
Environmental conditions:
Temperature: from 10°C to 40°C (50 to 104 °F)
Humidity (without condensation): from 20% to 80%
Electromagnetic immunity:
The product will function correctly if positioned at an adeguate distance distance of an
electromagnetic emission source (video, PC, etc..)
Power supply:
Machine: - In: 24 V dc
External power supply: - In: from 100 to 240 V 50/60 Hz
- Out: 24 V dc
- Power: 36 Watts
The power supply is switching on and it is supplied with the power cord of the right type
depending on the destination country.
Product size:
Width: 215 mm (8,47 in)
Depth: 125 mm (4,92 in)
Max. Height: 160 mm (6,30 in)
Weight:
Machine: 2 Kg (4,4 lb) for maximum configuration
Power supply: 0,3 Kg (0,661 lb)
Document features:
Height: from 50mm (1,97 in) to 105mm (4,3 in)
Length: from 100mm (3,94 in) to 216 mm (8,50 in)
Thickness: from 0.07mm (0,003 in) to 0.10mm (0,004 in)
Weight: from 70 g/mq (0,01 lb/sqf) to 110 g/mq (0,02 lb/sqf)
Image features:
Resolution: (100 dpi x 100 dpi) (3.93 X 3.93 ppmm)
(200 dpi x 200 dpi) (7.87 X 7.87 ppmm)
Grey scale: 256 or 16 grey levels
Illumination: RGB illumination
Software tools
Specific LS100 API interface, LSfamily scanners common API and API test program LS100 test
program which also includes calibration procedures.
All software tools and API work in: Windows XP / W2K / VISTA / 7 / 8 / 10 (x32 and x64 bit)
Linux
TWAIN driver available