User Manual – Arenal PCS – QA03-SDA Page 14/74
3.Installation
3.1 Generic configuration information
A complete Slurry Density Analyzer (SDA) and Slurry Massflow Analyzer (SMA) system comprises of the
following components:
1. QA03‐SDA or SMA. The analyzer can be separated into different parts, depending on the
requirements:
a) Housing
b) Power convertor
c) Main PCB board
d) IO Module
e) HMI
2. QT0161‐UDT – Ultrasonic Density Transmitter
3. QC013‐UDC ‐ Coaxial cable, in case of QP015‐UDP probe, this item is included and not mentioned in
the list
4. QC000‐QQ‐01000‐XXX‐XXX Connection cable 100m from UDT to QA03
5. QP013‐UDP ‐ Ultrasonic Density Probes for submersible applications
6. QP014‐UDP‐PRC – Small Ultrasonic Density Probe
7. QP015‐UDP – Ultrasonic Density Probes for mounting in spool pieces are wafer cells
8. QB03‐WFC – Wafer cell
9. QB05‐SWC – Steel wafer cell
10. QB06‐SPC – Spool Piece of carbon steel (QB06‐SPS is of Stainless Steel)
11. QS – Services: like Remote Monitoring Services, local service assistance, System Integration
Services, Spare Parts
12. When the massflow meter is supplied:
a) QT656‐TMT – Thermal Massflow Transmitter
b) QP654‐TMP – Thermal Massflow Probe
c) QC000‐QQ‐00100‐XXX‐XXX Connection cable from TMT to UDT
As the QA03‐SDA or SMA is the main part of every installation, where all settings are done and where all
information is gathered. Additional information, needed to set up the Ultrasonic Density Transmitters, can
be found in the enclosure of this manual.
3.2 Mounting
Arenal uses AluCase enclosure from Rolec Germany (www.rolec.de). To mount the enclosure to the wall, the
lid does not need to open. Just remove the aluminum panels on each side: they are clamped and easily
removable. Arenal supplies a mounting set in each delivery.