Operation Instructions
21
When this function has been activated, “On/Off” operation will be deactivated. By pressing On/Off , a window will
pop up, saying “Please disable the floor debug!".
When Floor debug” has been activated; “Weekly timer”, “Clock Timer”, “Temp timer” and “Preset mode” will
be deactivated.
Emergen. mode”, Disinfection”, “Holiday mode”, “Manual defrost”, “Forced mode” and “Refri. recovery”
cannot be activated at the same time with “Floor debug”. If doing so, a window will pop up, saying “Please disable the
floor debug!”.
Upon power failure, “Floor debug” will back to “Off” and the runtime will be zeroed.
When Floor debug” has been activated, “T-floor debug” and “Debug time” can be viewed.
When Floor debug” has been activated and works normally; the corresponding icon will be displayed at the
upper side of the menu page.
Before activating “Floor debug”, make sure “Segment time” of each segment is not zero. If so, a window will pop
up, saying “Segment time wrong!” In this case, “Floor debug” is allowed to be activated only when “Segment time
has changed.
2.4.11 Manual Defrost
[Operation Instructions]
At the commissioning parameter setting page, by touching “Manual defrost ”, the control panel will access to the
corresponding setting page.
[Notes]
This setting will not be memorized upon power failure.
This setting can be set only when the unit has turned off. When this function has been activated, ON operation is
un-allowed.
Defrosting will quit when the defrosting temperature goes to 20°C or the defrosting duration is equal to 10
minutes.
2.4.12 Force Mode
[Operation Instructions]
1. At the commissioning parameter setting page, by touching “Force mode”, the control panel will access to the
corresponding setting page.
2. At the “Force mode” setting page, it can be set to “Force-cool”, “Force-heat”, and “Off”. When it is set to
Force-cool” or “
Force-heat”, the control panel will directly go back to the homepage and response to any touching
operation except the ON/OFF operation, with a window popping up, sayingThe force-mode is running!”. In this case,
by touching ON/OFF, “Force mode” will quit.
[Notes]
This function is allowed only when the unit has just repowered and not turned on. For the unit which once has
been put into operation, this function is unavailable, alerting “Wrong operation!”.
It will not be memorized upon power failure.
2.4.13 Gate-Ctrl.
[Operation Instructions]
At the commissioning parameter setting page, by touching “Gate-Ctrl.”, the control panel will access to the
corresponding setting page.
[Notes]
When Gate-Ctrl.” has been activated; the display panel will detect the card state. When the card has inserted,
the unit will run normally. When the card is drawn out, the controller will turn off the unit at once and back to the
homepage. In this case, all touching operation become ineffective, and a prompt dialog box will pop up. The unit will
resume normal operation until the card has inserted back and the ON/OFF status of the control panel will resume to that
before the card is drawn out.
This setting will be memorized upon power failure.