CLIMIA
10
10 - PARAMETERS SETTING
(0.5 sec)
:
Par. Parameter name Min Default Max Values
P00 Factory default reset 0 0 3 0 = No action
1 = Reset all remote control parameters
to factory default value
P01 Software version 0 - 7 Software version of the remote controller
P05 Temperature scale 0 0 1 0 = °C (Celsius)
1 = °F (Fahrenheit)
P06 Transmission channel 0 0 3 0 = Channel #0
1 = Channel #1
2 = Channel #2
3 = Channel #3
P12 ECO mode power input limit 30 75 99 When ECO mode is selected, max electrical
power input of the unit is limited to P12:
Leistung auf P12 begrenzt:
0 = 30% of Max Power Input
31 = 31% of Max Power Input
...
99 = 99% of Max Power Input
NOTE
Parameters not listed in the table are reserved and should not be changed. Changing the parameters not listed can cause the air
conditioner to malfunction.
Press “ON/OFF” to go back to main screen: