1.5.4 Removing the pump
1. Remove the U-clips A1 and B1 (F
IG. 1.36);
2. Remove the retaining clip C1 (FIG. 1.37);
3. Release the nut D1 (FIG. 1.38);
4. Remove the pipe E1 (F
IG. 1.39);
5. Remove the screw F1 (FIG. 1.40);
6. Remove the pump (FIG. 1.41).
FIG.1.37
FIG.1.36
F
IG.1.38
C1
A1
B1
FIG
. 1.39
FIG. 1.40
FIG. 1.41
D1
E1
F1