39
once
Factory
setting
DISPLAY
A
CTION
C
ONFIGURATION
x times
Section Digit 1 Digit 2 Digit 3 and 4
Stop pump after burner stops 4 0
0 :
no
1 : yes
Pump speed 4 1
0 : High speed
1 : Low speed
Pump post circulation duration 4 2
0 to 5 min by step
0.5 min
4 3
Maximum Central Heating flow
temperature
4 4
50° to 80°
by steps of 1°
Minimum Central Heating flow
temperature
4 5
25° to 50°
by steps of 1°
4 6
CH anti-cycling delay 4 8
0 to 7 min by step
0.5 min
CH maximum output (range rating) 4 9
Value from 0 to 10
Pmin & Pmax general