40
Menu - 5 - Combustion rate control mode (test mode)
Effect Display
The combustion rate control mode will be inactive when :
- boiler is in stand-by mode
- room thermostat is not calling for heat
- boiler in lockout mode
- after the default settings have been restored or if the main supply fails (power cut)
- if the operator exits the 5th menu
- after 5 minutes if no buttons are pressed
Note : As soon as the combustion rate control mode is active, the Central Heating and Domestic Hot Water
control knobs become inactive.
DISPLAY
A
CTION
C
ONFIGURATION
C
ombustion rate control mode OFF
Combustion rate control mode ON The main exchanger temperature
appears on the display.
The digit - on the display shows the gas
o
utput level.
(Top = max, bottom = min).
Gas output setting To modify the gas output use the + and -
buttons.
To cancel the combustion rate control mode press the “Menu” button.
once
x times
once