Menu - 6 - Automatic heating regulation
DISPLAY
A
CTION
C
ONFIGURATION
once
x times
Factory
setting
Section Digit 1 Digit 2 Digit 3 and 4
Regulation on 6 0
0 : External sensor fitted
1 : External sensor not fitted
Heating setting in
a
utomatic/manual mode
6 1
0 : External sensor not fitted
1 : External sensor fitted
Thermal Curve setting
(see table
D, page 30)
6 2
0.3
0.5
1
1.2
1.5
2
2.5
3
Parallel Shift setting
(see table
E, page 30)
6 3
from 0 to 20
by steps of 1
In the event of connection of the external sensor, you must:
1. Activate the external sensor (menu 6.0)
2. Activate the external sensor automatic adjustment (menu 6.1)
3. Program the thermal curve (menu 6.2*)
4. Program the parallel shift (menu 6.3*)
*SEE SECTIONS 14.7 AND 14.8 (PAGE 31) FOR DETAILED INSTRUCTIONS ON SETTING THE THERMAL CURVE AND PARALLEL SHIFT.