H anti cycling delay setting :
If you would like to change the setting of CH anti cycling delay, if you want 3 min, proceed as follows:
(NOTE : THE FACTORY SETTING IS 2 MIN 30 SECONDS AND THE FOLLOWING EXPLANATION REFER TO MENU 4 SECTION 8)
Display
17. Adjustments and settings (continued)
1
5 ”
2
x 3
1
2
or
3
3
4
4
S
witch to installer mode, press button
and for 5 seconds, the
display shows :
10=0 if there is no
default in the default register.
Press 3 times on menu button
to
gain access to menu
4, the display
shows :
40=0 or 40=1
Change to section 8 (CH anti cycling
delay), press on button 8 times,
the display shows :
48=2.5 (factory
setting 2 min 30 seconds)
4 = menu 4
8 = section 8
2.5 = 2.5 min (2 min 30 seconds)
Press the setting button one
time, the 3rd and 4th digits flash
together,
Then press the
to
change the CH anti cycling delay, the
display shows :
48=3.0 press the setting button
to confirm the value. The display
stops flashing.
Setting procedure is finished.
To exit from setting mode, leave the
boiler for approx. 1 minute then the
PCB will switch back to user mode.
After programming please close the
front control panel cover
P (Fig. 43
page
36)
x 8