Page 42 Programming manual for RD6203
Function Code Sub-Event
Meaning
CD150/95
V6.0
CD91
V6.0
CD72
V6.0
CD34
V6.0
Cancel by Timeclock BC System 0 0 n/a n/a
Disarm by User OP/OR User 1-100 1-64 1-16 1-8,9
Disarm by Key OP/OR Zone 101-152 101-188 101-124 101-110
Disarm by TPC OP/OR System 0 0 0 0
Disarm by timeclock OA System 0 0 n/a n/a
Disarm by Action List OA List Number 1-12 1-12 n/a n/a
Local Programming LB/LS User 255 255 255 255
Programming - TPC LB/LS System 0 0 0 0
Manual Test RX Phone No. 1 - 4 1 - 4 1 - 4 1 - 4
Walk Test Pass/Fail WP/WF Area 1-8 1-4 n/a n/a
System Power Up RR System 0 0 0 0
AC Fault AT System 0 0 0 0
AC Restore AR System 0 0 0 n/a
Auxiliary Power
Fault/Restore
AT/AR Zone 1 - 152 1 - 88 n/a n/a
Battery Fault/Restore YT/YR System 0 0 0 0
Fuse Fault/Restore YT/YR Fuse 1 - 3 / 5 -
7
1 - 3 / 5 -
7
1 255
Remote Fault/Restore ET/ER Remote 1 - 16 1 - 8 1 - 6 1 - 4
Reset Alarm Digi QQ
Restores BR/MR/FR/
TR
Zone 1 - 152 1 - 88 1 - 24 1 - 10
Restore a confirmed
alarm (ACPO)
BW Zone 1 - 152 1 - 88 1 - 24 1 - 10
Remote Programming RB/RS/RU
Automatic Test RP System 0 0 0 0
Communications
Trouble
YS System
Trouble on
panel/dialler comms
YC System
Keypad PA Restore PR System 0 0 0 0