Programming manual for RD6203 Page 43
Contact ID
Table 16. Overview of the Contact-ID event codes
CODE EVENT REPORT
From
V6.11
132 BA/BR
Burglary alarm zone
573 BB/BU
Burglary alarm bridging zone
383 TA/TR
Tamper alarm zone
570 TB/TU
Tamper alarm bridging zone
121 HA/HR
Holdup activation user
122 PA/PR
Panic alarm zone/control panel
110 FA/FR
Fire alarm zone
571 FB/FU
Fire alarm bridging zone
100 MA
*
/MR
*
Medical alarm zone
150 ZA/ZR
Technical alarm zone
406 140 BC
Burglary alarm cancelled user
405 CE
Arming delayed 0
409 456 CF
Forced arm user
401 441 CG/CL
Partial/complete arming user
401 OP
Disarm after alarm user
401 406 OR
Disarm after alarm user
403 CP/OA
Arm/disarm by timer 0
404 454 OT
Armed late 0
401 451 OK
Disarmed early 0
300 LB
Local programming beginning (engineer present) user (engineer)
306 628 LS
Local programming finished (engineer absent) user (engineer)
411 RB
Up/Download beginning 1
412 RS
Up/Download finished 1
413 RU
Up/Download unsuccessful 1
602 RP
Test report 0
601 RX
Manual test report telephone number
305 RR
System started up (after power failure or watchdog
restart)
0
301 AT/AR
Mains fault or auxiliary power 0 or zone number
302 YR/YT
Battery low or fuse blown 0 or fuse
354 YS
‘No carrier’ fault in previous report 0
350 YC
Communication fault between panel and dialler 0
333 ER/ET
Remote fault control panel/ extension
607 WP/WF
Walk test pass and Walk test fail
134 EE
Exit fault
630 JS
Schedule changed
* Non ACPO option