AC25/30QTP-1 and -3 Operations Manual.... 13
Output Voltage Response Time 0.20 msec. 0.20 msec.
Continuous Output Current Refer to Table 3 on the following page for basic ratings.
Peak Output Current 400% of cont. rating 400% of cont. rating
Surge Output Current 250% of cont. rating 250% of cont. rating
Conversion Efficiency 89% @ rated load 89% @ rated load
4.1.2 Output Service, cont.
Table 3: Output Current, Rated Continuous RMS
Output Form AC25QTP-1
AC30QTP-1
1Ø, 220V
RMS
114A
RMS
136A
RMS
1Ø, 230V
RMS
109A
RMS
130A
RMS
1Ø, 240V
RMS
104A
RMS
125A
RMS
1Ø, 120/240V
RMS
104A
RMS
125A
RMS
Output Form AC25QTP-3
AC30QTP-3
3Ø, 120/208V
RMS
70A
RMS
83A
RMS
3Ø, 127/220V
RMS
66A
RMS
79A
RMS
3Ø, 220/380V
RMS
38A
RMS
45A
RMS
3Ø, 230/400V
RMS
36A
RMS
43A
RMS
3Ø, 240/416V
RMS
35A
RMS
42A
RMS

Table of Contents