V2000 – Installation Guide
U-0623-0291.docx – Issue: 04 complete, approved
Page 15 of 40
b. 1 x V2000-STBY Interface Card fitted:
Standard 2-way shortening link,
2.54 mm pitch
ASL PN 200028
(1 x 2.54 mm link)
2-pin shortening link,
5.08 mm pitch
(Harwin PN D3086-99)
ASL PN 208949
(4 x ‘handbag’ style links)
LINKS FITTED
(Top rear panel bar and bottom middle blanking plate not shown for clarity.)
Observe precautions for
handling electrostatic
sensitive devices.
LINKS FITTED
LINKS NOT FITTED
Ensure these links are NOT FITTED.
If fitted, amplifiers may get damaged when
the standby amplifier switches over.