V2000Installation Guide
U-0623-0291.docxIssue: 04 complete, approved
Page 19 of 40
13. Ensure that the mainframe ID is set to ‘01’
(factory default).
14. Ensure that the mains and battery supplies
to the mainframe are isolated.
a. Isolate the AC mains supply to the
unit by switching off the rack mains
isolator.
In racks fitted with ASL MDIST-
V2000 (Mains Power Distribution
Assembly), switch off the appropriate
16 A switch on the MDIST-2000; see
example on the right.
b. Isolate the DC supply to the unit by
switching off the battery supply circuit
breaker (if used).
In racks fitted with ASL BDIST-V2000
(Battery Power Distribution
Assembly), switch off the circuit
breaker on the BDIST-V2000; see
example on the right.
Mains
Battery
Aux Supply
Processor
Comms
Fault
Mainfram
ID
x1
x10
0
1
Mainframe ID: for future use
Mains supply isolator: example using ASL MDIST-V2000
DC supply isolator: example using ASL BDIST-V2000