Home
Assa Abloy
Garage Door Opener
SW300
Assa Abloy SW300 User Manual
5
of 1
of 1 rating
94 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
ASSA
ABLO
Y
as
word
and
logo
are
trademarks
owned
by
the
ASSA
ABLO
Y
Group
©
A
SSA
ABLO
Y
Entrance
Systems,
2021
T
echnical
data
subject
to
change
without
notice.
Backtrack
information:
folder:Workspace
Main,
version:a637,
Date:2021-02-03
time:11:19:02,
state:
Frozen
1
3
Table of Contents
Default Chapter
3
Table of Contents
3
1 Revision
7
2 Instructions for Safe Operation
8
3 Important Information
9
Intended Use
9
Safety Precautions
9
Electronic Equipment Reception Interference
9
Environmental Requirements
10
4 Technical Specifications
11
Permitted Door Weight and Door Width for ASSA ABLOY SW300
12
Permitted Door Weight and Door Width for ASSA ABLOY SW150
13
5 How the ASSA ABLOY SW300 and ASSA ABLOY SW150 Work
14
Opening
15
Closing
15
Control Switch
15
OFF/AUTO/OPEN Switch
15
Functions on the Basic Control Unit CU-300
15
Power Failure
15
Closing Torque
15
Extended Closing Torque (CLTQ)
16
Power Assist (POAS)
16
Push and Go (PAG)
16
ASSA ABLOY SW300 Inverse (INV)
16
Activation Delay (AD)
16
Overhead Presence Detector (OPD), Frame Mounted
16
Mat
16
Double Acting
17
Functions on the Extension Unit EXU-SI
17
KILL or FIRE Function
17
Function of Locks
17
Program Selector (Wall Mounted)
17
Impulses
17
OPEN/CLOSE Impulse
18
Power Failure Mode (Backup Batteries Are Installed) Optional
18
Nurse and Bed Functionality
19
Functions on the Extension Unit EXU-SA
19
Presence Impulse Approach, Door Mounted
19
Presence Detection Swingpath, Door Mounted
20
Monitored Safety Sensors
20
FIRE Input
20
Relay Output
20
6 Models
21
Single Operator, Surface Mounted
21
Double Operator, Surface Mounted
22
7 Part Identification
23
8 Arm Systems
25
Pushing Installation with PUSH-Arm
25
Pulling Installation with PULL-Arm
26
MM Extension
26
Pushing Installation with PULL-Arm
27
Double Acting Kits
28
Drive Shaft Extension Kits
29
9 Options
30
Control Switches
30
4-Position Switch PS-4C (Operates the Electric Lock)
30
Sync Cable for Double Doors (Synchronizing of 2 Operators)
30
Coordination Unit (Only for ASSA ABLOY SW300)
30
LED Cable
31
Battery Backup Unit
31
Cover Piece Kit
31
Closing Time Board Kit (Only for ASSA ABLOY SW300)
31
Fire Kit (Only for ASSA ABLOY SW300)
32
Mounting Plate (for Reinforcement of Wall)
32
Labels
33
10 Pre-Installation
34
General Tips/Safety Concerns
34
Operator/Door Handing
34
Installation Examples
35
Fastening Requirements (but Not Included)
35
Tools Required
36
11 Mechanical Installation
37
PUSH Arm System
41
PULL Arm System
47
Operator with Sliding PUSH Arm System
53
ASSA ABLOY SW300 Inverse Installation with PUSH Arm System
54
ASSA ABLOY SW300 Inverse Installation with PULL Arm System
55
Installation of Coordination Unit on Fire Door Installations
56
12 Electrical Connection
62
Control Units
64
Cu-300
64
Arm System Selection
64
Extension Units EXU-SI / EXU-SA
65
Extension Unit EXU-SI
66
Extension Unit EXU-SA
67
Installation on Double Doors
68
How to Cut the Jumper on the Sync Cable for Double Doors
68
Double Door Installations
69
Settings for Double Doors
69
Sensor Cable Inlet
70
Reset and Indication Device for Fire Doors
71
13 Start-Up
73
ASSA ABLOY SW300 Spring Pre-Tension
73
Micro Switch (Only for ASSA ABLOY SW300)
74
Adjusting the Door Stop
74
Auto-Learn-Automatically Sets Back and Latch Check (Recommended)
76
Push the LEARN BUTTON (LRN)
77
Double Doors
77
General Adjustment
77
Connection of Activation Units and Accessories
78
14 Cover
79
Fitting and Removing the Cover
79
Cover Piece Kit
79
15 Signage
80
16 Advanced Settings
81
Learn with Advanced Setting of "Back- and Latch-Check
81
Revert to Default Values for "Back- and Latch-Check" (Level 1)
81
Changing Group of Parameters (Level 2)
82
Classification (Level 3)
85
Overhead Presence Detection and Interlock (Level 4)
86
Enhanced Lock Kick, Fire Input and Extended Arm Selection (Level 5)
87
17 Guide for Installation and Adjustments
88
Complementary Safety Devices Swing Doors
88
Swing Doors Opening and Closing Time
88
How to Find the Correct Opening and Closing Time
88
Diagrams for Door Weight
89
Aluminium Frame with Glass
89
18 Troubleshooting
90
Error Indication
91
19 Service/Maintenance
92
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Assa Abloy SW300 and is the answer not in the manual?
Ask a question
Assa Abloy SW300 Specifications
General
Brand
ASSA ABLOY
Model
SW300
Closing Speed
10°/s
Hold-Open Time
Adjustable
Operating Temperature
-20°C to +55°C
Related product manuals
Assa Abloy Besam SW100
12 pages
Assa Abloy Besam SW300
14 pages
Highlands HI1000 - HI2000 - HI3000
8 pages
Norton D6001DE-R Double Unit Series
29 pages
Assa Abloy Besam PowerSwing CSDB
44 pages
Assa Abloy Albany RR1000
40 pages
Assa Abloy Norton D6061 Series
28 pages
Assa Abloy Norton D6021 Series
28 pages
Norton Double D6021 Series
28 pages
Norton Double D6031 Series
28 pages
Assa Abloy SW100
68 pages
Assa Abloy Besam SW200i US
82 pages