8 Arm systems
The installation process of arm systems is the same for Fire door installations, Basic installations
and Inverse installations.
8.1 Pushing installation with PUSH-arm
This arm system is delivered with drive arm, telescopic part and door fitting. It is used if the oper-
ator is installed on the wall on the opposite side of the door swing, and approved for fire door ap-
plication for A up to 300 mm.
Art. No.: 1007965BK/SI
Frame depth
Extension
345 mm extension
Art. No.: 173005BK/SI
230 mm extension
Art. No.: 173004BK/SI
Joint part
Art. No.: 173191
A = reveal
0-22 mmNone (Standard arm)
22-137 mmExtension L=345 mm
137-252 mmExtension L=230 mm + joint part
252-367 mmExtension L=345mm + 230 mm + joint part
25Issue 2021-02-041007913-en-20.0