Installation & Servicing instructions ATAG iR-Range
35
a CH system
The CH program is always active after start-up.
This is indicated by the upper
.
Ifthereisheatrequest,itisindicatedbyaashing
and the heating will be put into
operation
.
The circulation pump will switch on and the boiler will switch on after 1 to 2 minutes.
b Pump function
The central heating pump is wired to the pump electrical connections on the back of the control panel. See
gure10.a.
Danger of frost
If there is danger of frost damage to the CH installation, it is advisable to let the pump
run continuously.
By pressing both - buttons at the same time for 8 seconds the pump can be switched on
continuously.
If the pump is set to continuously this is displayed by
.
Boiler frost protection
Ifthe(T1)owsensorregistersatemperatureof5°Corbelowintheboiler,theboilerwillreup.Theboiler
keepsonringuntilthetemperaturereaches10°C(measuredontheowsensor)andtheboilerswitchesoff
again.
In this mode the
symbolwillash.