EasyManua.ls Logo

ATEQ F620 - Printer Mode

ATEQ F620
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sheet #652u – RS232
Version 1.00a User guide ATEQ 6th series Page 2/8
1.1. PRINTER MODE
The configuration menu of the link PRINTER
is displayed.
By using the
arrows, select
the menu to configure and validate with the
key.
+0%10(+
#761/45
Ź RS Parameters
Print Frame
Sending Cond.
Export : No
Print parameters
RS parameters: to configure the device for
dialog with the printer.
Transmit speed parameter.
Stop bit, number of bits and parity parameters.
These parameters must be the same as the
receiver device.
1/45452CTCOGVG
Ź Speed: 9600 Bds
1St/7 bits/even
Print frame: This function enables the
configuration of the result printout.
Associated parameters to be set:
¾PRESSURE (Display test pressure),
¾Prog. Name (Display program name
when set),
¾Date & Time (printing date and time),
¾Lines before (nb of lines before result),
¾Lines after (nb of lines after result),
¾Inter line (space between each line),
¾Form feed (new page).
61/452TKPV(TCO
Ź Pressure : No
Prog. name : No
Date & Time : No
Lines Before : 00
Lines After : 00
Inter Line : 00
Form feed : No
Sending conditions: With this function you
can choose which data is to be printed on the
results sheet.
Associated parameters to be set:
¾ALL RESULTS (all test results),
¾PASS (nb of pass parts),
¾T. FAIL (number of fail test parts),
¾R. FAIL (nb of fail reference parts),
¾ALARM (nb of alarm triggered),
¾PRESS OUT (nb of incorrect pressure),
¾REWORKABLE (nb of recoverable
parts),
¾CALIBRATION.
/455GPFKPI%QPF
Ź ALL RESULTS : Yes
PASS : No
T FAIL : No
R FAIL : No
ALARM : No
PRESSURE OUT : No
REWORKABLE : No
CALIBRATION : No