Note: Place the air-expansion roller in the bracket so that both ends are placed at the same time.
When removing the inflation roller from the holder, remove both ends at the same time.
(2)Unwinding device paper feeding sketch
Figure 5-11 Sketch of paper feeding
Note:When aligning the paper, align the edges of the paper, and make sure that the flat paper is attached
to the suction platform. The printing paper in the whole system should be in the same straight line.
5.4 Machine shutdown
5.4.1 Examination before shutdown
(1) Print the test strip: Make sure the nozzle is in the state and print the test strip to retain the sample (usually 2-3
weeks of test strip).
(2) Surface and periphery of the nozzle: Use a non-woven fabric to remove accumulated ink and dry dirt on the
surface and around it.
(3) Sprinkler moisturizing: Pour moisturizing liquid (deionized water or pure water) into the moisturizing tray.
5.4.2 Examination after shutdown
(1) Shut down according to the normal procedure and check if water, electricity and gas are off.