6.2.2 DL10 Device Replacement Procedures
The device replacement procedures are based on the following assumptions:
• The topology of the PROFINET network was properly dened with the PROFINET
engineering tool.
• The PROFINET controller supports automatic device replacement.
6.2.2.1 Master Module Replacement Procedures
1. Remove the “old” module from the Tool Changer or Utility Coupler, refer to
Section 3.2—Master Control/Signal Module Removal for removal procedure.
2. Install new module on Tool Changer, refer to Section 3.1—Master Control/Signal
Module Installation for installation procedure.
6.2.2.2 Replace a Master Module with an Already Commissioned Master
Module
Tools required: 5 mm Allen wrench, Phillips head screw driver, plastic stylus
Supplies required: Clean rag, Loctite 242
1. Remove the “old” module from the Tool Changer or Utility Coupler, refer to
Section 3.2—Master Control/Signal Module Removal for removal procedure.
2. Clean the mounting surfaces.
3. Using the ledge feature, place the Master control/signal module on the valve
adapter mounting surface. Align the control/signal module with the valve adapter
using the dowels in the bottom of the ledge feature.
4. Apply Loctite 242 to the (2) M6 socket head cap screws.
5. Install the (2) M6 socket head screws securing the control/signal module to the
valve adapter and tighten to 70 in‑lbs (7.9 Nm) using a 5 mm Allen wrench.