Do you have a question about the Atlantic Duolix Max and is the answer not in the manual?
Category | Fan |
---|---|
Voltage | 220-240 V |
Frequency | 50 Hz |
Speed Settings | 3 |
Remote Control | Yes |
Oscillation | Yes |
Model | Atlantic Duolix Max |
Max. flow 300 m3/h, certified electrical power 24.1 to 70.5 W-Th-C, max consumption 200 W.
Use a 3mm minimum contact opening, 2.5A bi-polar circuit breaker and 30mA differential circuit breaker for protection.
Connect to 230 VAC supply. The Duolix MAX is Class I and must be earthed. Use 1.5mm² dual-insulation cable.
Move control towards unit. A successful link shows 'OK'. If not, follow power-off/on procedure.
Access installer menu by pressing left/right arrows. First pages are important for house settings.
Manages optimum flow for energy saving and regulatory compliance. Adjusts extraction and air flow based on house configuration.
Use navigation arrows to modify imbalance. Left arrow reduces injection flow, right arrow increases it.
Use navigation keys to increase or reduce desired flow value during night cooling activation.
Control ground-connected heat exchanger valve. Supply fresh air from exchanger when external air is <5°C or >25°C.
Validate configuration ('End') or initialise ('Init') to return to factory settings. Save or reset parameters.
Control a valve for a ground-connected heat exchanger. Supply fresh air from exchanger when external air is <5°C or >25°C.
Switch off power. Remove fascia, unscrew screws, remove and clean exchanger. Clean condensation basin and fan turbines.