EasyManua.ls Logo

Atlantic Duolix Max - Adjusting the Imbalance; Adjusting the Night Cooling Flow

Atlantic Duolix Max
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Provide the control with the «Val 1» value from the
previous table.
Use the navigation arrows and to increase or
reduce the desired flow value.
Then validate the desired value by pressing
When the symbol OK appears, the choice is confirmed.
Provide to the control with the value «Val 2» from the
previous table.
Use the navigation arrows and to increase or
reduce the desired flow value.
Then confirm the desired value by pressing
When the OK symbol appears, the choice is confirmed.
5.4.3. Adjusting the imbalance
Use the navigation arrows and to modify the imbalance:
Pressing the left arrowreduces the air injection flow
(for an unchanged extracted air)
Pressing the right arrowincreases the air injection
flow (for unchanged extracted air);
Then validate the desired value by pressing
When the Ok symbol appears, the choice is confirmed.
5.4.4. Adjusting the night cooling flow
Use the navigation keysandto increase or reduce
the desired flow value during night cooling activation.
Then validate the desired value by pressing
When the Ok symbol appears, the choice is confirmed.
m
3
/h
Val
1
Max
m
3
/h
BOOST
m
3
/h
Val
2
m
3
/h

Table of Contents