A few minutes after stopping, the oil level should reach the bottom of the oil filler neck (FC).
If the oil level is too low, wait until the compressor has depressurized. Push the emergency stop
button (10) to avoid the compressor to start unexpectedly. Next, close the air outlet valve and
open the manual drain valve (Dm) until the air system between oil separator/air receiver vessel
and outlet valve is fully depressurized. See section Condensate system for location of the outlet
valve and water drain.
Unscrew oil filler plug (FC) one turn to permit any pressure left in the system to escape. Wait a
few minutes. Remove the plug and add oil until the level reaches the filler opening. Fit and tighten
the plug (FC).
Unlock the emergency stop button, select the STOP icon on the display and press reset before
restarting.
Regularly check that condensate is discharged during operation. See section Condensate
system. The amount of condensate depends on environmental and working conditions.
Regularly check the Elektronikon
TM
display: