‘Menu’ ‘Mod.’ ‘Del.’
F1 F2 F3
Press the key ‘Mod.’ (F2). The first two dashes will flash. Use the scroll keys (1) to enter 06. Press the
tabulator key (2) to jump to the following two dashes. Use the scroll keys to enter 15. Press the tabulator
key to jump to the row of dashes. Use the scroll keys to enter the command ‘Start’.
Press the key ‘Prog’ to program the command: ‘06:15 Start Compressor’.
Press the arrow down key (1): the horizontal arrow indicates that the second line is accessible. Press the
key ‘Mod.’ and modify this line in a similar way to the following command: ‘06:15 Setpoint 1’.
Press the key ‘Menu’ (F1) and scroll to ‘Friday’:
‘Thursday’
‘Friday’
‘Saturday’
‘Menu’ ‘Del.’
F1 F2 F3
Programming the command to change over at 18 o’clock to setpoint 2 is carried out in a similar way as
described above.
Press the key ‘Menu’ (F1) and scroll to ‘Saturday’. Programming the command ‘18:00 Compressor Stop’
is carried out in a similar way as described above.
Activating/deactivating the timer
The timer can only be activated if at least one start/stop command is programmed.
Starting from the Main screen, press the key ‘Menu’ (F1).
Use arrow down key (1) until the option ‘Modify Params’ is followed by a horizontal arrow.
Press the tabulator key (2) to activate the menu.
Use the arrow down key until the option ‘Clock Function’ is followed by a horizontal arrow, press the
tabulator key (2), the following screen appears:
‘Clock Function’
‘Not Activated’
.
‘Menu’ ‘Mod.’ ‘Del.’
F1 F2 F3
Press the key ‘Mod’, ‘Not Activated’ starts flashing.
Press the arrow down key (1) ‘Not Activated’ changes to ‘Activated’.
Press the key ‘Prog’.