System setup
9836 3043 01 13 (36)
PEAP, TKIP
PEAP, AES/CCMP
EAP/TLS, WEP128
EAP/TLS, TKIP
EAP/TLS, AES/CCMP
To setup the controller use ToolsTalk Power Focus or Graph interface and do the following settings:
1. Set parameter T290 Primary tool to IRC-W.
2. Set parameter T296 IRC-W operational mode to Infrastructure.
3. T293 Power Focus IP port is default 6677, and must be the same as in the tool.
Reboot Power Focus.
NOTE: It is possible to run IRC-W infrastructure on an IRC Focus.
3.5.3 Getting started with IRC-W Ad hoc
This is the default Operation mode for the IRC-W tool. If this setting has been changed, tool must be re-
programmed to ad-hoc, see 3.8Connecting tool with ToolsTalk Service. The Ad hoc mode makes it
possible to set up on which channel to communicate.
In ToolsTalk Power Focus do the following settings:
1. Set parameter T290 Primary tool to IRC-W.
2. Set parameter T296 IRC-W operational mode to Ad-Hoc.
3. Set T294 Serial port to Serial 2 if a Serial Port Adapter is used or Internal for IRC Focus.
4. Set parameter T297 IRC-W channel to the correct channel number. If Auto is selected the PF and the
tool will select the best available channel.
5. Reboot Power Focus.
6. Continue to section 3.6 Connecting tool with Power Focus (Pairing).