System setup
16 (36) 9836 3043 01
3.7 Setting up standalone
This can be done after setting up the tool communication according to section 3.5 Setting up tool
communication and performing a pairing. Standalone mode can be configured preferably when working
with IRC-B or IRC-W ad-hoc mode.
3.7.1 Getting started with Standalone
The STB power tool can be used in standalone mode, i.e., without being connected to the controller.
To setup the tool in standalone mode follow this instruction:
1. Start by pairing the tool and controller.
2. In the PF Map Tool branch, double-click on Maintenance and then click Standalone to view the
Standalone settings.
´
Figure 16 Standalone parameter settings
3. To edit the standalone parameters click Set
stand alone parameters.
4. In the Set Stand Alone Parameters dialog
box select the Use standalone check box,
and then select type of accessory.
None: Only one Pset can be used.
ST Selector: Up to four Psets are
available. The ST Selector must be
set to mode 1. To set up the ST
Selector, please refer to section
3.7.2 Setting ST-selector in stand-
alone modeFel! Hittar inte
referenskälla..
GPIO: Up to four Psets are
available.
5. Select a Pset for each position.
6. Click OK when finished to store the
standalone configuration to tool.
Figure 17 Standalone parameter settings

Related product manuals