Operation And Use 31
Kwik Bay
8.5 Manual Emergency Lowering (Optional)
In case of no electric power or power unit failure, lower the loaded vehicle
manually to its initial position as follows referring to the fi gure 17 and the fi gure
18:
• Padlock the power switch;
• If the safety is engaged, the safety should be released before lowering the
lift, operate the emergency hand pump (fi g.17 - 1) to raise the lift a little
bit to clear off the safety;
• Keep pressing the emergency button (fi g.18 - 1) on the solenoid air valve
in the control unit;
Fig. 17 Fig. 18
• Loosen the lowering solenoid valve by turning the emergency screw
(Fig. 17 - 2) anti-clockwise to lower the lift. The lowering speed can be
controlled by turning the screw more turns or less;
• Retighten the emergency screw by turning clockwise after lowering the lift
completely.
2
1
1