It is recommended that the appliance
electrical connections be tested once
a year by a qualied technician.
Aerator provided with 3kW models only
Assembly instructions
For optimal heating performance and proper
operation, the provided 0.5GPM aerator must
be installed to your sink faucet. This will ensure
a continuous ow and consistent, maximum
temperature rise. Output temperature will vary
depending on seasonality and inlet cold water
temperatures
Maximum of 0.5 GPM ow rate is needed for
optimal heating performance
Run the water ow for
one minute to check for
leakage before connecting
to power.
Reattach the front cover
of the heater and secure
it with 4 screws and then
slide the bottom gray cover
Connect the power cable to the
terminal block.
Caution: The heater must be
grounded.
Reference gure *3 on page 4 and
Electrical diagram on page 6
When installed outdoors,
the heater must be
placed in sealed
waterproof electrical box.
Make sure that the
appliance is lled with
water before connecting
power. (Repeat step 7)
12
11
13
Do not install the heater
where it may be subject to
direct sunlight.