EasyManuals Logo
Home>Atmor>Water Heater>InLine 800 Series

Atmor InLine 800 Series User Manual

Atmor InLine 800 Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Technical Information
Model Guide - kW Output
2
Model *Wattage Voltage Amperage Phase
Circuit breaker
size
Required wire
size
AT-800-35 3.0 kW 110 27 1 30 10 AWG
AT-800-04 3.8 kW 240 16 1 20 12 AWG
AT-800-70 7.0 kW 240 29 1 30 10 AWG
AT-800-08 8.5 kW 240 36 1 40 8 AWG
AT-800-10 10.5 kW 240 44 1 50 6 AWG
AT-800-13 13 kW 240 55 1 60 4 AWG
Minimum water ow to activate unit: 0.5 GPM
Nominal water volume: 2.7G/Min
Working pressure: 0.5 -8 bar (7 -115 psi)
Tested pressure: 16 bar (230 psi)
Water connections: 1/2" NPT
Dimensions (in) (H x W x D): 7.3 x 11.8 x 3.55
Weight (Ib): 3.4
Model 240V 220V 110V 120V
AT-800-04 3.8 kW 3.2 kW - -
AT-800-70 7.0 kW 5.4 kW - -
AT-800-08 8.5 kW 7.1 kW - -
AT-800-10 10.5 kW 8.8 kW - -
AT-800-13 13.0 kW 10.9 kW - -
AT-800-35 - - 3.0 kW 3.5 kW
* Wattage based on maximum voltage.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atmor InLine 800 Series and is the answer not in the manual?

Atmor InLine 800 Series Specifications

General IconGeneral
BrandAtmor
ModelInLine 800 Series
CategoryWater Heater
LanguageEnglish

Related product manuals