EasyManua.ls Logo

ATMOX ACE 2.0 - Apex Settings; Settings Menu

ATMOX ACE 2.0
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SETTINGS MENU
08
30
APEX SETTINGS
SETTINGS/TESTING
SCROLL: PRESS i
Press (i) to begin and keep scrolling through to next
setting.
APEX 03.XX.XX
APEX 01.XX.XX
Software version of display and controller.
WOOD SENSOR
ATTACHED Y
Set to (Y) or (N) depending on whether wood moisture
sensor is being installed.
Note: If you change to (Y) and press (i) and the wood
sensor is not installed properly or did not read correctly,
you will see a warning flash (SENSOR ERROR . . . CHECK
CONNECTION). This setting will remain at (N) and continue
to the next setting automatically. In order to retry, you must
begin at the beginning of the settings menu again.
WOOD MOISTURE
ALERT Y
Set to (Y) to allow an alert for high wood moisture.
WOOD MOISTURE
ALERT SET PT 20%
This set point determines when the alert for high wood
moisture will be triggered. Alert will not turn off until
wood moisture is 1% less than set point.
SNOW MODE
ENABLE N
Set to (Y) or (N) depending on whether this mode is
needed for your geographic area and your specific
house. See more information on this setting in
OPERATOR’S GUIDE section.
LIGHTS
OPERATE Y
Set to (Y) or (N) depending on whether lights on
GREEN output are being installed.
OUTPUT DETECTION
ALERTS Y
Change to (N) to remove any alert from Missing
Output Detection.
OUTPUT ERROR
RESET N
If the controller detects any type of issue with wiring
on an output, it will shut that output off as a safety
feature. Once the issue has been physically corrected,
the error must be cleared in the software by resetting
the output. To reset, change to (Y) and press (i) to
execute.
CAUTION: Once the output error is reset in the software,
then all alerts related to outputs are cleared. This does not
mean that the problem has definitively been solved. The
system will not know if there is still an issue until there is
a command to operate. You should go back through the
settings menu and test every output to make sure all errors
are corrected. If the error reoccurs, then the whole process
needs to be completed again.