TH303
19
Supply: 120/240 VAC, 60 Hz
Minimum load: 0.83 A (resistive only)
200 W @ 240 VAC
100 W @ 120 VAC
Maximum load: 10.4 A (resistive only)
2500 W @ 240 VAC
1250 W @ 120 VAC
Setpoint range:
5°C to 30°C (41°F to 85°F)
Display range: 0°C to 37°C (32°F to 99°F)
Setpoint/display resolution
: ±0.5°C (±1°F)
Operation: 0°C to 50°C (32°F to 120°F)
Storage
: -20°C to 50°C (-4°F to 120°F)
Permanent memory: You do not need to adjust the temperature settings or the thermostat’s
configurations following a power outage. However, you might need to
set the thermostat’s clock and date if the outage lasts more than
4hours.
ICES-003 Class B Notice - Avis NMB-3, Classe B
This Class B digital apparatus complies with Canadian ICES-003.