Installation Manual 40 Document #: LTRT-59811
MediaPack Series
c. Press the selected pattern code, and then press #
8. Press
to finish.
1
The following is an example perl CGI script, suitable for most Apache-based HTTP servers
for generating configuration dynamically per pattern #6 above. Copy this script to
/var/www/cgi-bin/acconfig.cgi on your Apache server and edit it as required:
to save, and then hang up the handset. The device retrieves the configuration
from the HTTP server.
#!/usr/bin/perl
use CGI;
$query = new CGI;
$mac = $query->param('mac');
$ip = $query->param('ip');
print "Content-type: text/plain\n\n";
print "; INI file generator CGI\n";
print "; Request for MAC=$mac IP=$ip\n\n";
print <<"EOF";
SyslogServerIP = 36.44.0.15
EnableSyslog = 1
SSHServerEnable = 1
EOF
The table below lists the configuration parameters that can be queried or modified using the
voice menu:
Table 3-2: Configuration Parameters Available via the Voice Menu
Item Number at
Menu Prompt
Description
IP address.
1
Subnet mask.
2
Default Gateway IP address.
3
Primary DNS server IP address.
4
DHCP enable / disable.
7
Configuration server IP address.
31
Configuration file name pattern.
32
Voice menu password (initially 12345).
99 Note: The voice menu password can also be changed using the Web interface
or ini file parameter VoiceMenuPassword (refer to the User's Manual
).

Table of Contents

Other manuals for AudioCodes MediaPack MP-118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-118 and is the answer not in the manual?

AudioCodes MediaPack MP-118 Specifications

General IconGeneral
CategoryGateway
Analog Ports8 FXS ports
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
ProtocolsSIP, MGCP, H.323
ModelAudioCodes MediaPack MP-118
Fax SupportT.38
ManagementWeb-based, SNMP, CLI
SecuritySRTP, TLS, HTTPS
Power SupplyAC 100-240V, 50-60Hz
Humidity10% to 90%, non-condensing
Network Interfaces2 x 10/100Base-T Ethernet