Electric Rotary Actuators 2SA7
Technical Data
Page 18 Y070.304/EN
4
2
4
1
4
0
2
8
2
9
3
0
3
1
32
3
3
3
4
3
5
1
2
3
4
5
6
7
8
9
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
9
1
8
1
7
1
6
1
5
1
4
1
3
1
2
1
1
1
0
4
3
4
4
4
5
4
6
4
7
5
0
3
7
3
8
3
9
U1
U2
V1
V2
W1
W2
4
8
4
9
3
6
Connections at round plug (plug assignment)
Inputs and outputs
ECOTRON PROFITRON
2SA7. 2SA70
2SA73
2SA75
Binary Inputs 2, 3, 4 and 5 2, 3, 4, 5,
9, 10 and 27
Outputs 16
1)
, 17, 19, 20, 21,
22 and 23
16
1)
, 17, 19, 20, 21, 22,
23, 24, 25 and 26
Analog Inputs --- 11 and 12 (option) 11 and 12 (option),
13 and 14 (option)
Outputs 7 and 8 7 and 8,
48, 49 and 50 (option)
Relay outputs
(option)
28, 29, 30, 31, 32, 33, 34, 35, 36,
37,40, 41, 42, 43 and 44
28, 29, 30, 31, 32, 33, 34, 35,
36, 37, 40, 41, 42, 43, 44, 45, 46 und 47
Fieldbus
(option)
1 channel 28, 29, 30 and 31 28, 29, 30 and 31
2 channel 28, 29, 30, 31,
32, 33, 34 and 35
28, 29, 30, 31,
32, 33, 34 and 35
Voltage output
„P24 int.“ resp. „P24 gal.“
1, 6,
15
1)
and 18
1)
1, 6,
15
1)
and 18
1)
Auxiliary 24 VDC supply for
electronics unit „P24 ext.“
38 and 39 38 and 39
Position recording
If the actuator is equipped with a signaling gear, position recording is performed via precision film potentiometer with microcontroller assessment.
The signaling gear reduces the revolutions required for travel to the permissible rotation angle of the precision film potentiometer.
For "non-intrusive – commissioning without opening the actuator" (without signaling gear), the position is recorded with utmost precision and is transmitted to the
microcontroller.
Positioner
Defining an analog position setpoint (0/4–20mA) for the positioner results in precise control of the position corresponding to this value.
The positioner works adaptively. This leads to a continuous automatic adaptation of the threshold value to the controlled system:
hysteresis 0.4% of the travel
response threshold (dead band) adjustable, default setting: 0.2 to 2.5 % of the travel
upward adaptation response threshold is enlarged by 0.1 %, if an OPEN ==> CLOSE ==> OPEN command sequence occurs within 6 seconds
downward adaptation response threshold is reduced by 0.01 %, when no control has taken place within 10.8 seconds
1) Not applicable for version with relay board.
XK
Plug assignment for the
external round plug connection